AXIOMET AX-EL300W60A [33/72] Auxiliary functions
![AXIOMET AX-EL300W60A [33/72] Auxiliary functions](/views2/1664975/page33/bg21.png)
set with the command (CURRent:PROTection < NRf+>). The specified delay time to turn off the input can
be set with the command (CURRent:PROTection:DELay < NRf+>).
3.14.4. Over Power
The electronic load provides software overpower protection function.
Once the input power exceeds the maximum rated power, the load will compute the present actual
power. The overpower protection will become active as long as the overpower time exceeds the specified
limit.
When the overpower protection is enabled, the input will be turned off with OPP displayed, mean-
while, the OP and PS status register bits are set, and will remain set until they are reset and overpower
condition is removed.
3.14.5. Over Temperature
If the internal temperature of the load exceeds safe limits, the overtemperature protection will be enabled;
the input will be turned off with OTP displayed, in the meantime, the OT and PS status register bits are
set, and will remain set until they are reset and overtemperature condition is removed. You must wait
until the load cools down to the normal temperature before you can reset the latched protection. The fans
in the load will help to cool the load as quickly as possible.
3.14.6. Reverse Voltage
When reverse voltage is applied, the reverse voltage protection will be enabled; the input will be turned
off and the indicator of “Cancel” is turned on, in the meantime, the RV and VF status register bits are set,
and will remain set until they are reset and reverse voltage is removed.
3.15. Auxiliary Functions
3.15.1. Trigger Function Selection
The Trigger Function in Trigger Set menu is used to select the trigger object. Selecting “Tran” is used to
trigger transient operation, and selecting “List ” is used to trigger sequence (list) operation.
3.15.2. Knob Function
The Knob in Config menu is used to enable/disable the knob function. Select On to enable the knob function,
and select Off to disable.
3.15.3. Key Sound
The Key Sound in Config menu is used to enable/disable the key sound. Select On to enable the key sound,
and select Off to disable.
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция