3.8. Triggered Operation
The triggered operation is mainly used to make the load keep synchronized with other test equipments or
events. This series electronic load provides various triggering modes, which can be applied to the following
occasions:
- Triggering a preset level
Transfers all pending preset levels to the immediate levels. For the presently active mode, the new level
will appear at the input at once if the input is turned on. For the modes which are not presently active, the
preset levels will not take effect at the input until the corresponding mode becomes active.
- Triggering a transient pulse
Gernerates a transient pulse in accordance with the preset transient parameters, when pulsed transient
operation is active.
- Triggering a transient toggle
Switches the input between the transient low level and transient high level in accordance with the preset
transient parameters, when the toggled transient operation is active.
- Triggering a list test
Enables the present list test when the list operation is active.
Three triggering methods are available for remote control: the *TRG and TRIGger commands. The Ex-
ternal trigger input terminal and “Shift”+“0Trigger” key on the front panel of the load can be used to
trigger(can generates a trigger signal to the electronic load).
The load has three triggering modes: BUS, EXTernal, and HOLD.
- The BUS mode: the trigger source is *TRG command.
- The EXTernal mode: Choose the External trigger input terminal or “Shift”+“0Trigger” key on the front
panel as the trigger source. The input signal at the External trigger input terminal is TTL, the falling edge
(signal) is triggered(can generates a trigger signal to the electronic load).
- The HOLD mode: Use the command TRIGger:IMMediate as the trigger source. At this time, all other
triggering methods including *TRG become invalid.
Note:
The command TRIGger:IMMediate can be used in all three triggering modes. The triggering modes can
be selected via the remote command only (TRIGger:SOURce BUS; TRIGger:SOURce EXTernal; TRIG-
ger:SOURce HOLD).
3.9. Input Control
3.9.1. Turn On/Off the Load
The input can be turned on/off by pressing “On/Off” key, or via the remote command (INPUT ON/OFF).
When input is in Off status, press “On/Off” to turn on the input of load and the indicator of “On/Off” is
turned on; When input is in On status, press “On/Off” to turn off the input of load and the indicator of
“On/Off” is turned off; Turning the input on/off does not affect the programmed settings.
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция