AXIOMET AX-EL300W60A [54/72] Clear protection settings

AXIOMET AX-EL300W [54/72] Clear protection settings
For the above operating procedures, the corresponding SCPI commands should be:
MODE CCL ; Sets the load to CCL status
CURR 2 ; Sets the current value to 2A
*SAV 0 ; Saves the present settings in location 0 in EEPROM
Example2: Based on the above example, set the mode to CVH; set the voltage value to 40V; recall the
values saved in location0 in EEPROM. The detailed operations are shown as below:
Procedures /// Operation Descriptions /// Display
1 /// Set the mode to CVH, set the voltage value to 40V (please refer to 4.5.2 section for detailed operations).
///
2 /// Press “Shift”+“2Recall”keys to enter into the recalling menu. /// RECALL 0
3 /// Press Entry keys or the knob to select the recalled location 0. /// RECALL 0
4 /// Press “Enter” key to confirm. ///
For the above operating procedures, the corresponding SCPI commands should be:
MODE CVH ; Sets the CVH mode
VOLT 40 ; Sets the voltage value to 40V
*RCL 0 ; Recalls the values saved in location 0 in EEPROM
5.11. Clear Protection Settings
The operating procedures for clear protection settings are shown as below:
1) Eliminate the reason that causes the protection status.
2) Press “Cancel” keys.
Example1: Clear RV protection of the load. The detailed operations are shown as below:
Procedures /// Operation Descriptions /// Display
1 /// Connect the power supply to the load again. ///
2 /// Long-press “Cancel” key. ///
For the above operating procedures, the corresponding SCPI commands should be:
INP:PROT:CLE ; Clears the protection status
5.12. Triggered Operation
When the triggering mode is EXTernal, the triggered operations are shown as below:
1) Set trigger object (please see 3.8 section for detailed introduction).
2) Press “Shift”+“0Trigger” keys or trigger terminal (TRIG IN) to receive low TTL level, and a trigger occurs.
Example: Select “List” for the trigger function to trigger a sequence operation. The sequence is
the one mentioned in Example in 5.8.1 section. The detailed operations are shown as below: