Daikin RXYQ16M7W1B [101/182] Capacity tables

Daikin RXYQ34M7W1B [101/182] Capacity tables
Inverter heat pump RXYQ5M7W1B, RXYQ8,10M8W1B
18
3
Systems Outdoor Units
100
3 Capacity tables
3-2 Heating capacity
3-2-5 14HP
TC: Total capacity; PI: Power Input
Combination (%) Capacity index
Outdoor
air temp.
Indoor air temperature: °CDB
16.0 18.0 20.0 21.0 22.0 24.0
TC PI TC PI TC PI TC PI TC PI TC PI
°CDB °CWBkWkWkWkWkWkWkWkWkWkWkWkW
50 175
-19.8 -20.0 21.2 13.3 21.2 13.6 21.2 13.9 21.1 14.1 21.1 14.1 19.6 13.0
-18.8 -19.0 22.3 13.6 22.2 13.8 22.2 14.1 21.8 13.9 21.1 13.3 19.6 12.2
-16.7 -17.0 24.4 14.0 23.9 13.9 22.5 12.9 21.8 12.4 21.1 11.9 19.6 11.0
-14.7 -15.0 25.4 13.5 23.9 12.6 22.5 11.7 21.8 11.3 21.1 10.8 19.6 9.98
-12.6 -13.0 25.4 12.3 23.9 11.5 22.5 10.7 21.8 10.3 21.1 9.91 19.6 9.15
-10.5 -11.0 25.4 11.3 23.9 10.6 22.5 9.85 21.8 9.50 21.1 9.15 19.6 8.46
-9.5-10.025.410.923.910.222.59.4821.89.1421.18.8119.68.15
-8.5 -9.1 25.4 10.5 23.9 9.84 22.5 9.17 21.8 8.85 21.1 8.53 19.6 7.90
-7.0 -7.6 25.4 9.96 23.9 9.33 22.5 8.71 21.8 8.40 21.1 8.10 19.6 7.51
-5.0 -5.6 25.4 9.31 23.9 8.73 22.5 8.16 21.8 7.87 21.1 7.60 19.6 7.05
-3.0 -3.7 25.4 8.77 23.9 8.23 22.5 7.70 21.8 7.44 21.1 7.18 19.6 6.67
0.0 -0.725.48.0523.97.5622.57.0821.86.8521.16.6119.66.16
3.0 2.2 25.4 7.46 23.9 7.02 22.5 6.58 21.8 6.37 21.1 6.15 19.6 5.74
5.0 4.1 25.4 7.12 23.9 6.71 22.5 6.29 21.8 6.09 21.1 5.89 19.6 5.50
7.0 6.0 25.4 6.82 23.9 6.42 22.5 6.03 21.8 5.84 21.1 5.65 19.6 5.28
9.0 7.9 25.4 6.54 23.9 6.17 22.5 5.80 21.8 5.62 21.1 5.44 19.6 5.08
11.0 9.8 25.46.2923.95.9322.55.5821.85.4121.15.2419.64.90
13.0 11.8 25.4 6.05 23.9 5.71 22.5 5.38 21.8 5.21 21.1 5.05 19.6 4.72
15.0 13.7 25.4 5.84 23.9 5.51 22.5 5.19 21.8 5.04 21.1 4.88 19.6 4.57
NOTE
1 is shown as reference
When selecting the unit models, avoid the Outdoor air temperature range shown by .