7.2 Capacity Correction Factor by the Length of Refrigerant Piping (Reference)
The cooling and the heating capacity of the unit has to be corrected in accordance with the length of
refrigerant piping. (The distance between the indoor unit and the outdoor unit)
< line: For the indoor unit with capacity of 2.5 kW.>
<--- line: For the indoor unit with capacity of 3.5 kW or more.>
Notes: 1. The graphs show the factor when additional refrigerant of the proper quantity is charged.
2. If it is for the multi-type room air-conditioner, the variation of the capacity will be smaller when only one
indoor unit is in operation.
Capacity correction factor
1
5101520
30
0.9
0.8
Cooling (R22)
Piping length (m)
(R2656)
25
Capacity correction factor
1
5101520 25
0.9
0.8
Heating (R22)
Piping length (m)
(R2506)