D-Link DGS-1210-28XS/ME [430/519] Show duld recover_timer

D-Link DGS-1210-52/ME rev.B [430/519] Show duld recover_timer
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
412
To configure the unidirectional link detection recovery time to 100 seconds:
DGS-1210-28MP/ME:5# config duld recover_timer 100
Command: config duld recover_timer 100
Success.
DGS-1210-28MP/ME:5#
show duld recover_timer
Purpose To display unidirectional link detection recover time.
Syntax
show duld recover_timer
Description
The show duld recover_timer command is used to display
unidirectional link detection recover time.
Parameters
[0 | <sec 60-1000000>] Specifies the recover time of unidirectional
link detection function.
Restrictions None.
Example usage:
To display the unidirectional link detection recovery time:
DGS-1210-28MP/ME:5# show duld recover_timer
Command: show duld recover_timer
DULD Recover Time : 100
DGS-1210-28MP/ME:5#