D-Link DGS-1210-28XS/ME [73/519] Config loopdetect

D-Link DGS-1210-28X/ME [73/519] Config loopdetect
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
55
Success.
DGS-1210-28MP/ME:5#
config loopdetect
Purpose To configure the loop back detection interval time and recover time
on the Switch.
Syntax
config loopdetect interval_time <value 1-32767>
lbd_recover_time [0 | <value 60-1000000>]
Description
The config loopdetect command configures the loop back
detection interval time and recover time on the Switch.
Parameters
interval_time <value 1-32767> − Specifies the interval time of loop
back detection. The range is between 1 and 32767 seconds.
lbd_recover_time [0 | <value 60-10000>] Specifies the recover
time of loop back detection on the switch. The range is between 60
and 10000 seconds.
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure the loop back detection with interval time 500 on the Switch:
DGS-1210-28MP/ME:5# config loopdetect interval_time 500
Command: config loopdetect interval_time 500
Success.
DGS-1210-28MP/ME:5#
show loopdetect
Purpose To display the loop back detection information on the Switch.
Syntax
show loopdetect {ports [<portlist> | all]}
Description
The show loopdetect command
displays the loop back detection
information on the Switch.
Parameters
<portlist> − A port or range of ports to be displayed.
all − All ports settings are to be displayed.
Restrictions None.
Example usage:
To display the loop back detection information on the Switch:
DGS-1210-28MP/ME:5# show loopdetect
Command: show loopdetect
Loopdetect Global Settings
--------------------------------------------
Loopdetect Status : Enabled
Loopdetect Mode : Port-Base