D-Link DGS-1210-28XS/ME [446/519] Config ssh server

D-Link DGS-1210-28XS/ME [446/519] Config ssh server
DGS-1210 Metro Ethernet Managed Switch CLI Reference Guide
428
DGS-1210-28MP/ME:5# show ssh authmode
Command: show ssh authmode
The SSH Authmode :
------------------------------------------------------------
Password : Enabled
Publickey : Enabled
Hostbased : Disabled
Success.
DGS-1210-28MP/ME:5#
config ssh server
Purpose To configure the SSH server.
Syntax
config ssh server [authfail <int 2-20> | contimeout <sec 120-
600> | maxsession <int 1-4> | rekey [10min | 30min | 60min |
never]]
Description
The config ssh server command configures the SSH server.
Parameters
authfail <int 2-20> - Specifies the authfail times. The value may be
between 2 and 20 times.
contimeout <sec 120-600> - Specifies the connection timeout. The
value may be between 120 and 600 seconds. The default is 600
seconds.
maxsession <int 1-4> Specifies the maxseeion of ssh server.
rekey [10min | 30min | 60min | never] Specifies the rekey time. The
possible values are 10min, 30min, 60min and never.
Restrictions Only administrator or operator-level users can issue this command.
Example usage:
To configure the SSH server:
DGS-1210-28MP/ME:5# config ssh server authfail 20 maxsession 1
Command: config ssh server authfail 20 maxsession 1
Success.
DGS-1210-28MP/ME:5#
show ssh server
Purpose To display the SSH server setting
Syntax
show ssh server
Description
The show ssh server command displays the current SSH server
settings.
Parameters None.
Restrictions None.
Example usage:
To display the SSH server: