Epson GT-9500 [39/54] Set gamma correction

Epson GT-9500 [39/54] Set gamma correction
7/8/96-B 37
Set gamma correction
(1) Code: ESC Z
ASCII: ESC Z i
decimal: 27,90 i
hexadecimal: 1B,5A i
(2) Function: This command specifies the gamma correction tables
according to the output devices.
i = 01H : CRT A / for bi-level data. (γ=1)
i = 02H : CRT B / for multi-level (8-bit) data. (γ=1.8)
i = 03H : User defined table (Ref. ESC z)
i = 00H : Printer A / High density printing.(24-dot mode)
i = 10H : Printer B / Low density printing. (8-dot mode)
i = 20H : Printer C / High contrast printing.
(Image and characters mixed)
Default value : i = 01H
(3) Handshaking
1) ESC Z code
2) ACK( 06H )
3) The parameter for gamma correction i.
Note1: If a User-Defined Table is selected, the Brightness parameter is not available.
Note2: If setting the parameter i=03h without having downloaded a user table,
Scanner sets the default table