Epson GT-9500 Инструкция по эксплуатации онлайн [52/54] 49850

50 7/8/96-B
(3) Fatal error
Cause: The lamp is broken.
Power is turned on before removing the transportation screw.
System breakdown.
Disposition: The lamp goes off and the scanner stops operation.
The bit 7 of the status byte is set.
Indicator: READY LED blinks.
ERROR LED blinks.
Remedy: Turn the scanner off and then back on.
Push the reset switch.
Send ESC @ codes to the scanner.
INIT signal in the parallel interface turns active.
RESET signal in SCSI turns active.
Complete BUS DEVICE RESET message in SCSI.
Acceptable command:
[ESC F, ESC f, ESC @]
(3) Option error (In the case of option unit is installed)
Cause: Unit cover open
Paper empty
Disposition: The bit 7 of the status byte is set.
Indicator: READY LED goes off.
ERROR LED goes off.
Remedy: Remove the error condition.