AXIOMET AX-EL300W60A Расширенная инструкция онлайн [51/72] 527990
![AXIOMET AX-EL600W120A Расширенная инструкция онлайн [51/72] 527987](/views2/1664975/page51/bg33.png)
Procedures /// Operation Descriptions /// Display
1 /// Press “List” key to enter into sequence operation menu. /// STATE 1 On
2 /// Use “↑”, “↓” keys to select Data:<New/Edit>. /// DATA 0 New
3 /// Use the knob to select Edit, press “Enter” to confirm and enter into the step edit screen. /// DATA 1
Edit
4 /// Use “ ” key to select time parameter and the time set value. /// NO 00
5 /// Use Entry keys or the knob together with “ ”, “ ” keys to input the time to 2s, and press “Enter” key
to confirm. /// DELAY 02.000S
6 /// Use “↑”, “↓” key to select the last new step (Step6). /// NO 05
7 /// Add a new step: CCH, 5A, 1s. Use Entry keys or the knob together with “ ”, “ ” keys to input time to
1s, and press “Enter” key to confirm. /// MODE CCH
8 /// Use the knob to select operating mode to CCH, and press “Enter” key to confirm. /// LEVEL 05.000A
9 /// Use Entry keys or the knob together with “ ”, “ ” keys to input the current value to 5A. Press “Enter”
key to confirm and enter into the next operation. /// DELAY 01.000S
10 /// Use “↑”, “↓” keys to select the step3. /// NO 02
11 /// Press “Shift”+“7Insert” keys to insert a new step at step3. /// NO 02
12 /// Insert a new step: CRL, 1Ω, 10s at step3. The setting operations for this new step are the same as
the operating procedures7 to 9. /// NO 02
13 /// Use “↑”, “↓” keys to select the step2. /// NO 01
14 /// Press “Shift”+“8Delete” keys to delete the step2. /// NO 01
15 /// Press “Cancel” keys to exit the step edit screen and save the sequence data in EEPROM assigned by
the sequence number. /// DATA 1 Edit
16 /// Use “↑”, “↓” keys to select chain. /// CHAIN Off
”17 /// Use Entry keys or the knob to input 0 (it is chained o itself to realize continuous execution). Press
“Enter” key to confirm and save the Chain value in EEPROM assigned by the sequence number.
/// CHAIN 0”
18 /// Press “Cancel” key to exit sequence operation menu. ///
5.8.3. Starting/Stopping the Sequence (List)
Example: Start the No.0 sequence, and stop the active sequence operation.
Procedures /// Operation Descriptions /// Display
1 /// Press “List” key to enter into sequence operation menu. /// STATE 1 On
2 /// Use “↓” key to select No..Use Entry keys or knob to set the sequence number (No.) to 0, and press
“Enter” key to confirm (recall the sequence in EEPROM assigned by the sequence number). /// No. 0
3 /// Press “Cancel” key to exit sequence operation menu. ///
4 /// Press “Shift”+“4Start” keys to activate sequence operation. (the other operations will be active only
when the sequency operation is disabled.) ///
5 /// Press “Shift”+“5Stop” keys to stop sequence operation. ///
Содержание
- Ax el300w programmable dc electronic load operation manual 1
- General introduction 1
- Function features 2
- Production models 2
- Front panel 3
- Message of lcd display 3
- Rear panel 4
- Keypad function 5
- Display messages 9
- Functions and features 10
- Local and remote control 10
- Remote programming 10
- Basic test function 11
- Main function 11
- Transient operation 18
- Sequence list operation 22
- Battery discharge operation 23
- Short circuit operation 24
- Input control 25
- Triggered operation 25
- Measurement function 29
- Saving and recalling 30
- Reading remote programming errors 31
- Status report 31
- Protection function 32
- Auxiliary functions 33
- Connections on the rear panel 34
- Environment installation location 34
- Initial check 34
- Installation 34
- Power on self test 34
- Connections on the front panel 36
- Wiring 36
- Local control 38
- Local operation 38
- Main operation on the front panel 38
- Basic tests 39
- Connecting to the power supply 39
- Turning the input on off 39
- Short circuit operation 44
- Transient operation 45
- Sequence list operation 48
- Battery discharge operation 52
- Saving and recalling 53
- Clear protection settings 54
- Triggered operation 54
- Main menu 55
- Communication interface 59
- Remote control annunciators 59
- Remote programming operation 59
- Sending a remote command 59
- Cc mode example 60
- Remote programming commands 60
- Returning data 60
- Continuous transient operation example 61
- Cr mode example 61
- Cv mode example 61
- Auto test operation 62
- Main menu 62
- Pulsed transient operation example 62
- Function description 63
- Lcd display message 63
- Local operation 63
- Main specifications 67
Похожие устройства
- AXIOMET AX-EL300W Инструкция
- AXIOMET AX-EL300W Расширенная инструкция
- PEAKTECH PKT-P3690 Инструкция по эксплуатации
- PEAKTECH PKT-P3725 Инструкция по эксплуатации
- AXIOMET AX-C709 Инструкция
- AXIOMET AX-C709 Расширенная инструкция
- AXIOMET AX-C708 Инструкция
- AXIOMET AX-C708 Расширенная инструкция
- PEAKTECH PKT-P4390 Инструкция по эксплуатации
- AXIOMET AX-C850 Расширенная инструкция
- AXIOMET AX-C850 Инструкция
- AXIOMET AX-C830 Расширенная инструкция
- AXIOMET AX-C830 Инструкция
- AXIOMET AX-C800 Расширенная инструкция
- AXIOMET AX-C800 Инструкция
- AXIOMET AX-C705 Расширенная инструкция
- AXIOMET AX-C705 Инструкция
- AXIOMET AX-C605 Расширенная инструкция
- AXIOMET AX-C605 Инструкция
- AXIOMET AX-6003P Инструкция