Samsung RB37A52N0SA [64/101] Troubleshooting

Samsung RB37A52N0SA [64/101] Troubleshooting
64
4. TROUBLESHOOTING
5) When the Cool Select Zone sensor is defective (CSZ models only)
ERROR CODE
MAIN PCB Connector
CN30 is inserted properly?
Cool Select Zone
Sensor is normal?
Voltage between
MAIN PCB Connector CN30- "2"(BLK)
and "7"(GRY)
Input Voltage at IC10
MICOM Pin #26 is normal?
Start
PCB and Temp Sensor are normal.
Check the connector contact.
Connector contact defect /
Reconnect
Replace Temp Sensor
Check the wire connection
Check Soldering Defect & Short
No
No
No NO (0.6V > Value or Value > 4.6V)
No
Yes
Yes
Yes
Yes
Sensor MICOM/Connector #
F DEF
Between Connector CN30"-
"2"(BLK) and CN30-"7"(GRY)
Voltage : Between 4.6V ~ 0.6V
** Sensor Resistance Reading Location **
CSZ : Between CN30 #2 and #7
** 0Ω : Short / ∞Ω : Open
Voltage at IC10 MICOM #
26 is the same as the value
between CN30-"2"(BLK) and
CN30-"7"(GRY).
Refer to Circuit Diagram
DATA1. Temp Table

Содержание

Похожие устройства

Скачать