Delta Electronics R1-EC5621 [37/49] Shutdown option code 605bh

Delta Electronics R1-EC5621 [37/49] Shutdown option code 605bh
R1-EC5621 User Guide Chapter 6 Object Dictionary
October, 2014 6-11
6.6.4 Shutdown Option Code (605Bh)
This object shall indicate what action is performed if there is a transition from
Operation Enabled state to Ready to Switch on state.
Index
Sub
Index
Name
Data Type
Access
PDO Mapping
Value
EEPROM
605Bh
0
Statusword
INT
RW
No
0
No
Data Description
Data Description
Disable drive function (transit into Switch On Disabled).
6.6.5 Disable Operation Option Code (605Ch)
This object shall indicate what action is performed if there is a transition from
Operation Enable state to Switched on state.
Index
Sub
Index
Name
Data
Type
Access
PDO
Mapping
Value
EEP-
ROM
605Ch
0
Disable operation option code
INT
RW
No
0
No
Data Description
Data Description
Disable drive function (transit into Switch On Disabled).
6.6.6 Modes of Operation (6060h)
This object shall indicate the requested operation mode.
Index
Sub
Index
Name
Data
Type
Access
PDO
Mapping
Value
EEPROM
6060h
0
Modes of operation
SINT
RW
No
0 to 10
No
Data Description
Data Description
No mode change / No mode assigned
Profile Position mode
Homing mode
Cyclic Sync Position mode
6.6.7 Modes of Operation Display (6061h)
This object shall provide the actual operation mode. The operation mode that
corresponds to the feedback value is identical to 6060h
Index
Sub
Index
Name
Data
Type
Access
PDO
Mapping
Value
EEPROM
6061h
0
Modes of operation display
SINT
RO
No
0
No

Содержание