Fluke 1760 [93/110] W warning

Fluke 1760 [93/110] W warning
Options and Accessories
Accessories 6
6-15
General Characteristics
Maximum conductor size: Diameter: 15 mm
Bus bar: 15 x 17 mm
Cable length: 2 m
Operating temperature range: 10 °C - +55 °C
Storage temperature range: 20 - +70 °C
Operating humidity: 15 % - 85 % (non-condensing)
Weight (per clamp): Approx. 220 g
Order-number: 2540450
Reference Conditions
Environment temperature range: +18 °C to +26 °C.
Humidity: 20 up to 75 % r.h.
Current: Sinusoidal waveform with 48 to 65 Hz.
Distortion factor: < 1 %, no DC component, stray field < 40 A/m,
conductor centered within the clamp jaws
Safety Standards
IEC/EN 61010-1 2
nd
edition
IEC/EN 61010-2-032
IEC/EN 61010-031
EMC Standards
EN 61326 –1: 1997/A1: 1998.
W Warning
Utilize the clamps only on insulated conductors, max. 600 V
r.m.s. or DC to ground and frequencies below 1 kHz.