Daikin FCQ71B7V3B [276/381] Removal of fan motor

Daikin FUQ71BUV1B [276/381] Removal of fan motor
Disassembly and Maintenance ESIEN05-04
5–36 Part 5 Disassembly and Maintenance
3
1
55
1.11.8 Removal of Fan Motor
Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step
Procedure Points
Q Remove the terminal block
box cover according to the
procedure for removing the
switch box, then disconnect
the following connectors.
Transfer connector
z Wired remote control
z Swing motor
z Humidity sensor
Connector built in the
switch box
z Connector used for
power supply cables
1 Removing the bell mouth.
1 Disconnect the 2 remote
control cables and 3
power supply cables.
2 Disconnect the drain
pump and float switch
wiring from bell mouth.
(
*1)
3 Remove the 5 mounting
screws on the bell mouth.
*1: At this time, do not cut the
clamp material attached to the
drain pan near the switch box.
Loosen the mounting screw to
remove the clamp material.
For heat pump
For float switch
Remote
controller
cable
Power supply cable