Daikin EHYHBX08AFV3 [119/252] Configuration

Daikin EHYHBX08AFV3 [119/252] Configuration
8 | Configuration
Installer reference guide
119
EVLQ05+08CAV3 + EHYHBH05AF + EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
8 Configuration
8.1 Indoor unit
8.1.1 Overview: Configuration
This chapter describes what you have to do and know to configure the system after
it is installed.
Why
If you do NOT configure the system correctly, it might NOT work as expected. The
configuration influences the following:
The calculations of the software
What you can see on and do with the user interface
How
You can configure the system using two different methods.
Method Description
Configuring via the user
interface
First time – Quick wizard. When you turn ON the user
interface for the first time (via the indoor unit), a quick
wizard starts to help you configure the system.
Afterwards. If necessary, you can make changes to
the configuration afterwards.
Configuring via the PC
configurator
You can prepare the configuration off-site on PC and
afterwards upload the configuration to the system
with the PC configurator.
See also: "To connect the PC cable to the switch
box"[4120].
INFORMATION
When the installer settings are changed, the user interface will request to confirm.
When confirmed, the screen will shortly turn OFF and "busy" will be displayed for
several seconds.
Accessing settings – Legend for tables
You can access the installer settings using two different methods. However, NOT all
settings are accessible via both methods. If so, the corresponding table columns in
this chapter are set to N/A (not applicable).
Method Column in tables
Accessing settings via the breadcrumb in the menu
structure.
#
For example: [A.2.1.7]
Accessing settings via the code in the overview
settings.
Code
For example: [C-07]
See also:
"To access the installer settings"[4120]
"8.1.5Menu structure: Overview installer settings"[4169]