Qtech QSW-8200-28T-POEAC- DC [54/85] Ethernet oam mode

Qtech QSW-8200-28T-POEAC- DC [54/85] Ethernet oam mode
User Manual
Chapter 8. Commands for EFM OAM 54
www.qtech.ru
8.20 ethernet-oam mode
Command: ethernet-oam mode {active | passive}
no ethernet-oam mode
Function: Configure the mode of OAM function, no command restores the default
value.
Parameters: active, active mode
passive, passive mode
Command Mode: Port mode
Default: active mode.
Usage Guide: At least one of the two connected OAM entities should be configured to
active mode. Once OAM is enabled, the working mode of OAM cannot be changed and
you need to disable OAM function if you have to change the working mode.
Example: Set the mode of OAM function on ethernet 1/0/4 to passive mode.
Switch(Config-If-Ethernet1/0/4)#ethernet-oam mode passive
8.21 ethernet-oam period
Command: ethernet-oam period <seconds>
no ethernet-oam mode
Function: Configure the transmission period of Information OAMPDU, no command
restores the default value.
Parameters: <seconds>, sending period, ranging from 1 to 2 seconds.
Command Mode: Port mode
Default: 1s.
Usage Guide: Use this command to configure the transmission interval of Information
OAMPDU which keep OAM connection normally.
Example: Set the transmission interval of Information OAMPDU for ethernet 1/0/4 to
be 2s.
Switch(Config-If-Ethernet1/0/4)# ethernet-oam period 2
8.22 ethernet-oam remote-failure
Command: ethernet-oam remote-failure
no ethernet-oam remote-failure
Function: Enable remote failure indication of OAM, no command disables the function.
Parameters: None.
Command Mode: Port mode
Default: Enable.
Usage Guide: With remote failure indication is enabled, if critical-event or link fault
event is occurred locally, it will notify the peer by sending Information OAMPDU, log
the fault information and send SNMP trap warning. When the remote failure indication