Haier AS09SH1ERA [5/109] Warning
Содержание
- Service manaul p.1
- Dc inverter free match s series p.1
- Wall mounted type p.1
- Model no as09 12sh1era p.1
- U09 12eh1 era p.1
- Table of contents p.2
- Safety cautions p.4
- Model name explanation p.4
- Introduction p.4
- Warning p.5
- Introduction p.5
- Domestic air conditioner p.5
- Caution in repair p.5
- Warning p.6
- Introduction p.6
- Domestic air conditioner p.6
- Cautions regarding products after repair p.6
- Warning p.7
- Caution p.7
- Inspection after repair p.7
- Domestic air conditioner p.7
- Introduction p.7
- Î caution caution p.8
- Warning warning p.8
- Using icons list p.8
- Using icons p.8
- T note note p.8
- Reference p.8
- Introduction p.8
- Icon type of information description p.8
- Domestic air conditioner p.8
- Caution p.8
- List of fuctions p.9
- Specifications p.10
- Domestic air conditioner p.10
- As09sh1era 1u09eh1 era as12sh1era 1u12eh1era p.10
- Conversion formulae p.11
- W 52 52 p.11
- U09eh1era 1u12eh1era p.11
- The data are based on the conditions shown in the table below p.11
- Specifications p.11
- Snb130fgym2 snb130fgym2 p.11
- Domestic air conditioner p.11
- Cooling heating piping length p.11
- Indoor unit connectors p.12
- Outdoor unit p.13
- Connectors p.13
- Lo о o p.15
- Funcitions and control p.16
- Dehumidifying mode p.16
- Cooling operation mode p.16
- Automatic operation p.16
- Main functions and control specification of indoor unit p.16
- Heating operation mode p.17
- Timing p.18
- Strength operation p.18
- Mute operation p.18
- Dormant operation p.18
- Air refreshing p.18
- Urgent on off input p.19
- Low load protection control p.19
- High load protection control p.19
- Abnormal operation of indoor system p.19
- Malfunction list resume p.20
- Single indoor system operation p.20
- Power cut compensation p.20
- Fixed frequency operation p.20
- Abnormality confirmation approaches p.20
- Time cutting function p.21
- Test program p.21
- Ifp optional function p.22
- Temp display p.23
- Degree heating maintaining p.23
- The starting of compressor p.24
- The speeds of increasing or decreasing the frequency of the compressor p.24
- The operation frequency of outdoor unit and its control p.24
- The operation frequency control of compressor p.24
- The calculation of the compressor s frequency p.24
- Main functions and control specification of outdoor unit p.24
- The outdoor fan control when refrigerating or dehumidifying p.26
- The outdoor fan control when heating p.26
- The outdoor fan control exchange fan p.26
- The control of the outdoor electronic expansion valve eev p.26
- Four way control p.27
- Ttc high temperature preventing protection p.27
- Tc high temperature preventing control of the indoor heating unit p.27
- Protection function p.27
- The protection function of ac current p.28
- The control of preventing the over current of the compressor p.28
- Anti freezing protection of the indoor heat exchanger p.28
- The frequency limitation of modification rate p.29
- Temperature protection of the outdoor refrigerating coil p.29
- Function of main thermistor p.30
- B exhaust temperature sensor c indoor heat exchange sensor p.30
- A outdoor suction temperature sensor p.30
- Value of thermistor 5 intdoor unit p.31
- Room sensor and pipe sensor p.31
- R25 c 10kq 3 b25 c 50 c 3700k 3 p.31
- Haier ____________ p.31
- Ambient sensor suction sensor defrosting sensor p.34
- R25 c 10kq 3 p.34
- Outdoor unit p.34
- B25 c 50 c 3700k 3 p.34
- Function control p.35
- Domestic air conditioner p.35
- Function control p.36
- Domestic air conditioner p.36
- Function control p.37
- Domestic air conditioner p.37
- Function and control p.38
- Domestic air conditioner p.38
- Discharging sensor p.38
- C 50kq 3 p.38
- 80 c 4450к 3 p.38
- Function and control p.39
- Domestic air conditioner p.39
- Function and control p.40
- Domestic air conditioner p.40
- Function and control p.41
- Domestic air conditioner p.41
- System configuration p.42
- Instruction p.42
- Remote controller p.43
- Parts and functions p.43
- Outdoor unit p.43
- Indoor unit p.43
- Operation p.44
- Loading of the battery p.44
- Clock set p.44
- Smart operation cool heat and dry operation p.45
- Operation p.45
- Operation p.46
- Select tempsetting fan operation swing operation p.46
- The setting of p.47
- The health airflow function p.47
- The cancel of p.47
- Press health button p.47
- Operation p.47
- Notice p.47
- Health operation health airflow operation p.47
- Health airflow function p.47
- Power soft operation timer operation p.48
- Operation p.48
- Operation p.49
- Comfortable sleep p.49
- Operation p.50
- Fresh operation emergency operation and test operation p.51
- For smart use of the air conditioner p.51
- Operation p.51
- Cautions p.52
- A warning p.52
- A caution p.52
- Trouble shooting p.53
- Cautions p.53
- Before asking for service check the following first p.53
- Symptom check item details of measure p.54
- Service diagnosis p.54
- Problem symptoms and measures p.54
- Caution for diagnosis p.54
- Error codes and description p.55
- Thermistor or related abnormality p.56
- Indoor ac fan motor malfunction p.57
- Indoor dc fan motor malfunction p.59
- How to check fan motor dc p.59
- Outdoor dc fan motor fault p.61
- Ipm protection p.62
- The communication fault between ipm and outdoor pcb p.64
- Malfunction p.65
- Be sure to turn off power switch before connect or disconnect connector or p.65
- Else parts damage may be caused p.65
- Conditions p.65
- Troubleshooting p.65
- Overheat protection for discharge temperature p.65
- Method of p.65
- Faulty thermistor p.65
- Faulty pcb p.65
- Electronic expansion valve defective p.65
- Detection p.65
- Conditions p.66
- Be sure to turn off power switch before connect or disconnect connector or p.66
- Troubleshooting p.66
- Method of p.66
- Malfunction p.66
- Faulty pcb p.66
- Faulty eeprom data p.66
- Faulty eeprom p.66
- Else parts damage may be caused p.66
- Eeprom abnormal p.66
- Detection p.66
- Communication error between the indoor and outdoor units p.67
- An abnormal voltage rise or fall is detected by specified voltage checking p.69
- Malfunction p.69
- Detection circuit p.69
- Detection p.69
- Conditions p.69
- An voltage signal is feedback from the voltage detection circuit to the p.69
- Troubleshooting be p.69
- To turn off power switch before connect or disconnect connector or p.69
- Supply voltage not as specified p.69
- Power supply over or under voltage fault p.69
- Microcomputer p.69
- Method of p.69
- Loop of the station detect error p.70
- Over current of the compressor p.71
- High work intense protection p.72
- Mismatching between indoor and outdoor units p.73
- Short of refrigerant p.74
- Method of p.75
- Malfunction p.75
- High work intense protection p.75
- Detection p.75
- Conditions p.75
- Preparation p.77
- Installation manual of room air conditioner p.77
- Installation p.77
- Drawing for the installation of indoor and outdoor units p.77
- Domestic air conditioner p.77
- Other direction piping p.78
- Making a hole on the wall and fitting the piping hole cover p.78
- Left left rear piping p.78
- Installation of the indoor unit p.78
- Installation p.78
- Indoor unit p.78
- Fixing the indoor unit body p.78
- Fitting of the mounting plate and positioning of the wall hole p.78
- Drawing of pipe p.78
- Domestic air conditioner p.78
- When the mounting plate is fixed side bar and lintel о connecting the indoor outdoor electric cable p.78
- Accessory parts p.78
- When the mounting plate is first fixed p.78
- When connecting the cable after installing the indoor unit p.78
- Unloading of indoor unit body p.78
- Selection of pipe p.78
- Removing the wiring cover p.78
- Rear piping p.78
- Purging method to use vacuum pump p.79
- Outdoor unit p.79
- Installation of outdoor unit p.79
- Installation p.79
- Domestic air conditioner p.79
- Connection of pipes p.79
- Connection p.79
- Attaching drain elbow optional p.79
- Caution p.80
- Removal procedure p.81
- Removal of front panel p.81
- Indoor unit p.81
- Removal of filter and blade p.83
- Removal of front grill p.84
- Removal of drain pan p.86
- Removal of display assembly p.87
- Removal of vertical blades and swing motor p.88
- Removal of electrical box p.89
- Removal of heat exchanger p.90
- Removal of fan rotor and fan motor p.92
- Removal procedure p.93
- Removal of outdoor panel p.93
- Outdoor unit p.93
- Domestic air conditioner p.93
- Loosen the screws of the panel p.95
- Removal of electrical box p.96
- Removal of fan and fan motor p.97
- Removal of fan motor bracket and partition p.98
- Removal procedure p.99
- Domestic air conditioner p.99
- Removal of compressor and heat exchange p.100
- В1им11111 p.101
- Fil il m p.101
- Piping diagrams p.102
- Heating mode p.102
- Cooling mode p.102
- Appendix p.102
- Outdoor wtrtng diagram p.104
- Outdoor unit 01 p.104
- Control board circuit diagrams p.105
- Control board circuit diagrams p.106
- Module board circuit diagram p.108
- Sincere forever p.109
- Haier group p.109
Похожие устройства
-
Haier HME 09 TW03Инструкция по эксплуатации -
Haier HME 09 AW03Инструкция по эксплуатации -
Haier HSE 20 TW03Инструкция по эксплуатации -
Haier HSE 20 AW03Инструкция по эксплуатации -
Haier HSE 17 TW03Инструкция по эксплуатации -
Haier HSE 17 AW03Инструкция по эксплуатации -
Haier HSE 16 TW03Инструкция по эксплуатации -
Haier HSE 16 AW03Инструкция по эксплуатации -
Haier HSE 12 TW03Инструкция по эксплуатации -
Haier HSE 12 TD03Инструкция по эксплуатации -
Haier HSE 12 AH03Инструкция по эксплуатации -
Haier HSE 9 TW03Инструкция по эксплуатации
Haief Introduction 1 2 1 Caution in Repair Warning Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for a repair Working on the equipment that is connected to a power supply can cause an electrical shook If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits do not touch any electrically charged sections of the equipment e If the refrigerant gas discharges during the repair work do not touch the discharging refrigerant gas The refrigerant gas can cause frostbite When disconnecting the suction or discharge pipe of the compressor at the welded section release the refrigerant gas completely at a well ventilated place first If there is a gas remaining inside the compressor the refrigerant gas or refrigerating machine oil discharges when the pipe is disconnected and it can cause injury If the refrigerant gas leaks during the repair work ventilate the area The refrigerant gas can generate toxic gases when it contacts flames The step up capacitor supplies high voltage electricity to the electrical components of the outdoor unit о Be sure to discharge the capacitor completely before conducting repair work A charged capacitor can cause an electrical shock Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or fire Do not repair the electrical components with wet hands Working on the equipment with wet hands can cause an electrical shock Do not clean the air conditioner by splashing water Washing the unit with water can cause an electrical shock Be sure to provide the grounding when repairing the equipment in a humid or wet place to avoid electrical shock Be sure to turn off the power switch and unplug the power cable when cleaning the equipment The internal fan rotates at a high speed and cause injury Do not tilt the unit when removing it The water inside the unit can spill and wet the furniture and floor Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repairwork Working on the unit when the refrigerating cycle section is hot can cause burns Haier Domestic air conditioner 2
![Haier AS12SH1ERA [5/109] Warning](/views2/1812078/page5/bg5.png)