Ŷ Use only blades specified in this manual, complying
with EN 847-1.
Ŷ 2EVHUYH WKH PD[LPXP VSHHG PDUNHG RQ WKH VDZ
blade. Ensure the speed marked on the saw blade is at
least equal to the speed marked on the saw.
Ŷ Always use blades with correct size and shape of
arbour holes. Blades that do not match the mounting
hardware of the saw will run eccentrically, causing loss
of control.
Ŷ Do not use blades of larger or smaller diameter than
recommended. Do not use any spacers to make the
blade fit onto the spindle.
Ŷ Check the tips of the saw blade for damage or abnormal
appearance before each use. Tips that are damaged or
loose can become flying objects in use and increase the
chance of personal injury.
Ŷ Do not use cracked or distorted saw blades. Do not use
saw blades that are damaged or deformed
Ŷ Scrap the saw blade if damaged, deformed, distorted or
cracked, repairing is not permitted.
Ŷ Do not use HSS blades
Ŷ Ensure the saw blade is mounted correctly, tighten the
DUERUQXWVHFXUHO\EHIRUHXVHWLJKWHQLQJWRUTXHDSSUR[
12-15 Nm).
Ŷ Fastening screw and nuts shall be tightened using the
appropriate spanner, etc.
Ŷ ([WHQVLRQRIWKHVSDQQHURUWLJKWHQLQJ XVLQJKDPPHU
blows is not permitted.
Ŷ Make sure the blade and flanges are clean and the
recessed sides of the collar are against the blade.
Ŷ Make sure the blade rotates in the correct direction.
Ŷ Before work, make a dummy cut without the motor
turned on so the position of the blade, operation of the
guards with respect to other machine parts and work
piece may be checked.
Ŷ Never leave the machine unattended.
Ŷ Do not apply lubricants on the blade when it is running.
Ŷ Never perform any cleaning or maintenance work when
the machine is still running and the head is not in the
rest position.
Ŷ Never attempt to stop a machine in motion rapidly
by jamming a tool or other means against the blade.
Serious accidents can be caused unintentionally in this
way.
Ŷ Disconnect the saw from the mains supply before
changing blades or carrying out maintenance.
Ŷ Pay attention to blade packing and unpacking, it is easy
to be injured by the sharp blade tips.
Ŷ Use a blade holder or wear gloves when handling a saw
blade.
Ŷ Keep and store the blade in original packaging or other
suitable packaging. Keep in dry conditions and away
from chemicals which may damage the blade.
LASER SAFETY RULES
Ŷ The laser radiation used in this saw is Class 2 with
PD[LPXPP:DQGQPZDYHOHQJWKV'RQRWVWDUH
into the laser beam. Failure to comply with the rules
could result in serious personal injury.
Ŷ Do not stare into beam during operation.
Ŷ Do not project the laser beam directly into the eyes of
others. Serious eye injury could result.
Ŷ Do not place the laser in a position that may cause
anyone to stare into the laser beam intentionally or
unintentionally.
Ŷ Do not use optical tools to view the laser beam.
Ŷ Do not operate the laser around children or allow
children to operate the laser.
Ŷ Do not attempt to repair the laser device by yourself.
Ŷ Do not attempt to change any parts of the laser device
by yourself.
Ŷ Any repairs must only be carried out by the laser
manufacturer or authorized service agent.
Ŷ Do not replace the laser with a different type.
RESIDUAL RISKS
Even when the product is used as prescribed, it is still
impossible to completely eliminate certain residual risk
factors. The following hazards may arise and the operator
should pay special attention to avoid the following:
Ŷ risk of contact with uncovered parts of the rotating saw
blade;
Ŷ kick-back of work pieces or parts of work pieces due to
improper adjustment or handling;
Ŷ catapulting of faulty carbide tips from the saw blade;
Ŷ damage to the respiratory system.
NOTE: Wear respiratory protection masks containing
filters appropriate to the materials being worked.
Ensure adequate workplace ventilation. Do not eat,
drink or smoke in the work area.
Ŷ damage to hearing if effective hearing protection is not
worn.
WARNING
Dust from certain paints, coatings and materials may
cause irritation or allergic reactions to the respiratory
system. Dust from wood such as oak, beech, MDF and
others are carcinogenic. Material containing asbestos
VKRXOG RQO\ HYHU EH ZRUNHG RU SURFHVVHG E\ TXDOL¿HG
specialist operators.
WARNING
Injuries may be caused, or aggravated, by prolonged
use of a tool. When using any tool for prolonged periods,
ensure you take regular breaks.

Содержание

Похожие устройства

English Use only blades specified in this manual complying with EN 847 1 Observe the maximum speed marked on the saw blade Ensure the speed marked on the saw blade is at least equal to the speed marked on the saw Always use blades with correct size and shape of arbour holes Blades that do not match the mounting hardware of the saw will run eccentrically causing loss of control LASER SAFETY RULES The laser radiation used in this saw is Class 2 with maximum 1mW and 650nm wavelengths Donotstare into the laser beam Failure to comply with the rules could result in serious personal injury Do not stare into beam during operation Do not project the laser beam directly into the eyes of others Serious eye injury could result Do not use blades of larger or smaller diameter than recommended Do not use any spacers to make the blade fit onto the spindle Do not place the laser in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Check the tips of the saw blade for damage or abnormal appearance before each use Tips that are damaged or loose can become flying objects in use and increase the chance of personal injury Do not use optical tools to view the laser beam Do not use cracked or distorted saw blades Do not use saw blades that are damaged or deformed Scrap the saw blade if damaged deformed distorted or cracked repairing is not permitted Do not use HSS blades Ensure the saw blade is mounted correctly tighten the arbor nut securely before use tightening torque approx 12 15 Nm Fastening screw and nuts shall be tightened using the appropriate spanner etc Do not operate the laser around children or allow children to operate the laser Do not attempt to repair the laser device by yourself Do not attempt to change any parts of the laser device by yourself Any repairs must only be carried out by the laser manufacturer or authorized service agent Do not replace the laser with a different type RESIDUAL RISKS Extension of the spanner or tightening using hammer blows is not permitted Even when the product is used as prescribed it is still impossible to completely eliminate certain residual risk factors The following hazards may arise and the operator should pay special attention to avoid the following Make sure the blade and flanges are clean and the recessed sides of the collar are against the blade risk of contact with uncovered parts of the rotating saw blade Make sure the blade rotates in the correct direction kick back of work pieces or parts of work pieces due to improper adjustment or handling Before work make a dummy cut without the motor turned on so the position of the blade operation of the guards with respect to other machine parts and work piece may be checked Never leave the machine unattended Do not apply lubricants on the blade when it is running Never perform any cleaning or maintenance work when the machine is still running and the head is not in the rest position Never attempt to stop a machine in motion rapidly by jamming a tool or other means against the blade Serious accidents can be caused unintentionally in this way Disconnect the saw from the mains supply before changing blades or carrying out maintenance Pay attention to blade packing and unpacking it is easy to be injured by the sharp blade tips Use a bladeholder or wear gloves when handlings saw blade Keep and store the blade in original packaging or other suitable packaging Keep in dry conditions and away from chemicals which may damage the blade catapulting of faulty carbide tips from the saw blade damage to the respiratory system NOTE Wear respiratory protection masks containing filters appropriate to the materials being worked Ensure adequate workplace ventilation Do not eat drink or smoke in the work area damage to hearing if effective hearing protection is not worn A WARNING Dust from certain paints coatings and materials may cause irritation or allergic reactions to the respiratory system Dust from wood such as oak beech MDF and others are carcinogenic Material containing asbestos should only ever be worked or processed by qualified specialist operators A WARNING Injuries may be caused or aggravated by prolonged use of a tool When using any tool for prolonged periods ensure you take regular breaks