Zyxel OLT2412 [166/326] Command description

Zyxel OLT2412 [166/326] Command description
Chapter 23 VLAN Stacking and Translation
OLT2412 User’s Guide
166
vlan-translation name
<name>
[ing-ovid <vid>] [ing-ivid
<vid>] [ing-opri <pri>]
[ing-ipri <pri>] [egr-svid
<vid>] [egr-cvid <vid>]
[egr-spri <pri>] [egr-cpri
<pri>] [N1map <group>]
[cross-connect
<enable|disable>] [cross-
port <aid>] [tr156 <on|off>]
[active <on|off>]
Create a VLAN translation rule (with the specified name) on the
port.
vid: VLAN ID, 1~4094.
pri: Priority (0~7), lower numbers are higher priority.
The ingress parameters (ing-xxxx) mean the VLAN tag of the
target traffic to which the OLT applies this translation rule. That is
the ingress (incoming, upstream) packets coming from the
subscribers.
ing-ovid <vid>: The outer tag of incoming packets.
ing-ivid <vid>: The inner tag of incoming packets.
ing-opri <pri>: The outer priority of incoming packets.
ing-ipri <pri>: The inner priority of incoming packets.
The OLT applies the egress parameters (egr-xxxx) to the egress
(outgoing) packets going out the uplink ports towards the
backbone network.
egr-svid <vid>: The Service provider VID (outer) tag of
outgoing packets.
egr-cvid <vid>: The Customer VID (inner) tag of outgoing
packets.
egr-spri <vid>: The Service provider (outer) priority of
outgoing packets.
egr-cpri <vid>: The Customer (inner) priority of outgoing
packets.
N1map <group>: Use a group ID (1~16384) to map multiple
ingress (ing) VLANs to one egress (egr) VLAN. All VLAN
translation rules with the same N1map group ID must use the
same egress VLAN.
cross-connect <enable|disable>: Connect this rule’s
VLAN on this port to another port. The OLT ignores the MAC
address of ingress packets and forwards them by VID to the
cross-connected port. The OLT does not need to learn a
destination MAC address before forwarding packets for it to the
cross-connected port. No other ports can be members of the
VLAN. You cannot use N1map and cross connect in the same
VLAN translation rule.
cross-port <aid>: Cross connect connects this rule’s VLAN
on this port to another port. Specify the other port here.
tr156 <on|off>: Turns TR156 mode on or off. TR156 mode
adds a VLAN tag based on the GEM tag of incoming upstream
packets.
active <on|off>: Turns the VLAN translation rule on or off.
vlan-xlate-miss-drop
Enable upstream VLAN translation miss drop on the port. The
OLT discards incoming tagged packets from the subscribers that
do not match an entry in the VLAN translation table.
egr-vlan-xlate-miss-drop
Enable downstream VLAN translation miss drop on the port. The
OLT discards outgoing tagged packets destined for the
subscribers that do not match an entry in the VLAN translation
table.
Table 86 VLAN Translation Commands (continued)