Zyxel OLT2412 [245/326] Remote management command example

Zyxel OLT2412 [245/326] Remote management command example
Chapter 32 Access Control
OLT2412 User’s Guide
245
32.16 Remote Management Command Example
This example allows computers in subnet 172.16.37.0/24 to access the OLT through any service
except SNMP, allows the computer at 192.168.10.1 to access the OLT only through SNMP, and
prevents other computers from accessing the OLT at all.
OLT2412# configure
OLT2412(config)# remote-management 1 start-addr 172.16.37.0 end-addr
--> 172.16.37.255 service telnet ftp http icmp ssh https
OLT2412(config)# remote-management 2 start-addr 192.168.10.1 end-addr
--> 192.168.10.1 service snmp
OLT2412(config)# exit

Содержание