Zyxel OLT2412 [73/326] Port setup commands examples

Zyxel OLT2412 [73/326] Port setup commands examples
Chapter 7 Basic Settings
OLT2412 User’s Guide
73
7.6.1 Port Setup Commands Examples
The following commands configure port 1 on a card installed in slot 6.
Select port 1 in slot 6 and name the port 2412.
Set the port to 1 Gb and full duplex.
Set the port to forward BPDUs it receives.
flow-control
Enables flow control on the interface.
A concentration of traffic on a port decreases port bandwidth
and overflows buffer memory causing packet discards and
frame losses. Flow Control is used to regulate transmission of
signals to match the bandwidth of the receiving port.
The OLT uses IEEE 802.3x flow control in full duplex mode and
backpressure flow control in half duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a
pause signal to the sending port, causing it to temporarily stop
sending signals when the receiving port memory buffers fill.
Backpressure flow control is typically used in half duplex mode
to send a "collision" signal to the sending port (mimicking a
state of packet collision) causing the sending port to
temporarily stop sending signals and resend later. Select Flow
Control to enable it.
bpdu-control
<peer|tunnel|discard|network>
Sets how Bridge Protocol Data Units (BPDUs) are used in STP
port states. Configure the way to treat BPDUs received on this
port. You must activate bridging control protocol transparency
first.
peer: process any BPDU (Bridge Protocol Data Units) received
on this port.
tunnel: forward BPDUs received on this port.
discard: drop any BPDU received on this port.
network: process a BPDU with no VLAN tag and forward a
tagged BPDU.
Table 28 Port Setup Commands (continued)
COMMANDS DESCRIPTION
OLT2412# configure
OLT2412(config)# interface port-channel ge-6-1
OLT2412(config-interface)# name 2412
OLT2412(config-interface)# speed-duplex 1000-full
OLT2412(config-interface)# bpdu-control tunnel