Zyxel OLT2412 [69/326] Switch setup

Zyxel OLT2412 [69/326] Switch setup
Chapter 7 Basic Settings
OLT2412 User’s Guide
69
This example looks at the current time server settings.
The following table describes the labels in this display.
7.3 Switch Setup
Use these commands to configure OLT switch setup.
OLT2412# show timesync
Time Configuration
-----------------------------
Time Zone :UTC -600
Time Sync Mode :USE_DAYTIME
Time Server IP Address :172.16.37.10
Time Server Sync Status:CONNECTING
Table 24 show timesync
LABEL DESCRIPTION
Time Zone This field displays the time zone.
Time Sync Mode This field displays the time server protocol the OLT uses. It displays
NO_TIMESERVICE if the time server is disabled.
Time Server IP Address This field displays the IP address of the time server.
Time Server Sync Status This field displays the status of the connection with the time server.
NONE: The time server is disabled.
CONNECTING: The OLT is trying to connect with the specified time server.
OK: Synchronize with time server done.
FAIL: Synchronize with time server fail.
Table 25 Switch Setup Commands
COMMAND DESCRIPTION
vlan-type <802.1q>
Specifies the VLAN type. Currently the OLT supports IEEE
802.1q VLAN.
bcp-transparency
Enables Bridge Control Protocol (BCP) transparency on the
OLT. This allows the OLT to handle bridging control protocols
(STP, for example).
no bcp-transparency
Disables BCP transparency on the OLT.