Zyxel OLT2412 [277/326] Uni port pvid settings

Zyxel OLT2412 [277/326] Uni port pvid settings
Chapter 39 Remote ONT
OLT2412 User’s Guide
277
This example shows protocol-based VLAN rules on ONT-5-1-3 uniport-1-1.
39.9.4 UNI Port PVID Settings
Use the pvid command to configure UNI port default VLAN settings.
This example sets up PVID on uniport-1-1 of ONT-5-1-3. Untagged packets from port 1 of ONT-5-1-
3 will be tagged by the ONT with VID 203 and priority bit 2.
This example deletes the PVID on uniport-1-1 of ONT-5-1-3.
This example shows the PVID setting on uniport-1-1 of ONT-5-1-3.
OLT2412# show remote uniport uniport-5-1-3-1-1 protocol-based
Uniport Ether type Vlan Priority
----------------- ---------- ---- --------
uniport-5-1-3-1-1 ipoe 103 4
uniport-5-1-3-1-1 pppoe 203 0
uniport-5-1-3-1-1 arp 103 4
Table 161 UNI Port PVID Command Parameters
LABEL DESCRIPTION
remote uniport <aid>
Configure UNI port settings.
aid: uniport-<slot>-<pon>-<ont>-<card>-<port>
pvid
[VID|SVID:CVID]
[def-pbit
<priority>]
[active <on |
off>]
Configure default VLAN settings for the UNI port.
VID|SVID:CVID: The default VLAN ID the ONT applies to untagged packets it
receives from the subscriber ports.
def-pbit: The priority bit (0~7) the ONT inserts in the packets to which it
applies the PVID.
active: Enable or disable the PVID rule.
no pvid
Deletes default VLAN settings for the UNI port.
show remote uniport
<aid> pvid <cr>
Display the specified UNI port’s default VLAN settings.
aid: uniport-<slot>-<pon>-<ont>-<card>-<port>
OLT2412 (config)# remote uniport uniport-5-1-3-1-1
OLT2412 (config-remote-uniport)# pvid 203 def-pbit 2 inactive
OLT2412 (config)# remote uniport uniport-5-1-3-1-1
OLT2412 (config-remote-uniport)# no pvid
OLT2412 # show remote uniport uniport-5-1-3-1-1 pvid
Active: Yes
port default vlan and priority:
pvid is 203
pri is 2