Chapter 45 Troubleshooting
OLT2412 User’s Guide
303
After you have resolved the issues on the rogue ONT, you can use the no O7-state <ont-serial-
number> command to have the OLT reaccept the ONT’s traffic.
45.2 Error Logs Troubleshooting
Use show logging to display all logs. For example:
This table describes the format of a log message.
This table lists the log severity levels from high to low.
This table lists all log types.
OLT2412(config)# interface olt pon-5-1
OLT2412(config-rogue)# no O7-state 414C434C00050017
OLT2412# sh logging
1 Sep 25 10:53:16 IN authentication: CLI user admin login
2 Sep 25 10:46:49 CR system: System voltage has recovered to normal state
3 Sep 25 10:35:56 CR system: FAN(SMALL_1) FAN(SMALL_2) FAN(SMALL_3) FAN(SMALL_4) FAN(BIG_1) FAN(BIG_2)
RPM value 0 is out of its
4 Sep 25 10:10:51 EM system: BCM53003 POWER BCM56544 temperature value 160 is out of its limit range
5 Sep 25 09:49:53 NO system: System cold start
6 Sep 25 09:48:52 IN system: [poncard-5 ] Downloading...
7 Sep 25 09:40:58 IN system: [linecard-12] Detected
8 Sep 25 09:38:29 IN authentication: CLI user admin login
9 Sep 25 09:29:29 DE interface: Port ge-5-1 link up
Table 173 A Log Message Format
INDEX DATE AND TIME SEVERITY CATEGORY MESSAGE CONTENT
2 Sep 25 10:46:49 CR system: System voltage has recovered to normal state
Table 174 Log Severity Levels
CODE SEVERITY
0 EM: Emergency, the system is unusable.
1 AL: Alert, action must be taken immediately.
2 CR: Critical, the system condition is critical.
3 ER: Error, there is an error condition on the system.
4 WA: Warning, there is a warning condition on the system.
5 NO: Notice, there is a normal but significant condition on the
system.
6 IN: Informational, the syslog contains an informational message.
7 DE: Debug, the message is intended for debug-level purposes.
Table 175 Log Types
SYSTEM
INTERFACE
SWITCH
IP