9.7 GARP Configuration
Switches join VLANs by making a declaration. A declaration is made by issuing a Join message
using GARP. Declarations are withdrawn by issuing a Leave message. A Leave All message
terminates all registrations. GARP timers set declaration timeout values.
9.7.1 GARP Commands Summary
The following section lists the commands for this feature.
9.7.2 GARP Command Examples
In this example, the administrator looks at the OLT’s GARP timer settings and decides to change
them. The administrator sets the Join Timer to 300 milliseconds, the Leave Timer to 800
milliseconds, and the Leave All Timer to 11000 milliseconds.
VLAN Port Port VID This is the VLAN ID assigned to untagged frames that this port
received.
Acceptable Frame
Type
You may choose to accept both tagged and untagged incoming
frames, just tagged incoming frames or just untagged
incoming frames on a port.
Ingress filtering If set, the OLT discards incoming frames for VLANs that do not
have this port as a member.
Table 43 IEEE 802.1Q VLAN Terminology (continued)
VLAN PARAMETER TERM DESCRIPTION
Table 44 GARP Commands Summary
COMMAND DESCRIPTION
show garp
Displays GARP information.
garp join <100-65535> leave
<200-65535> leaveall <200-65535>
Configures GARP time settings (in milliseconds), including the
join, leave and leave all timers for each port. Leave Time must be
at least two times larger than Join Timer, and Leave All Timer
must be larger than Leave Timer.
OLT2412# show garp
GARP Timer
------------------------
Join Timer :200
Leave Timer :600
Leave All Timer :10000
OLT2412# configure
OLT2412(config)# garp join 300 leave 800 leaveall 11000
OLT2412(config)# exit
OLT2412# show garp
GARP Timer
------------------------
Join Timer :300
Leave Timer :800
Leave All Timer :11000