Zyxel OLT2412 [55/326] Chapter 5 initial setup

Zyxel OLT2412 [55/326] Chapter 5 initial setup
Chapter 5 Initial Setup
OLT2412 User’s Guide
55
5.6 Looking at Basic System Information
Use show system-information to display general system information about the OLT including the
firmware version.
Use show hardware-monitor to display OLT temperature, fan speeds and voltage. For example:
OLT2412# show system-information
Product Model : OLT2412
System Name : OLT2412
System Contact :
System Location :
System up Time : 0:23:26 (22540 ticks)
Ethernet Address : 00:19:cb:13:57:25
Bootbase Version : V0514 | 2013-05-14
Current ZyNOS F/W Ver. : V400VHB1b14 | 2013-08-22
ZyNOS F/W-1 Version : V400VHB1b14 | 2013-08-22
ZyNOS F/W-2 Version : V4.00(VHB.1)b12 | 2013-08-02
RomRasSize : 7749574
Current running Image : 1
setting Image : 1
Current running Config : 1
setting Config : 1
OLT2412# show hardware-monitor C
FAN Speed(RPM) Current Max Min Threshold Status
-------------- ------- --- --- --------- ------
FAN(SMALL_1) 0 0 0 1000 Error
FAN(SMALL_2) 0 0 0 1000 Error
FAN(SMALL_3) 0 0 0 1000 Error
FAN(SMALL_4) 0 0 0 1000 Error
FAN(BIG_1) 0 0 0 1000 Error
FAN(BIG_2) 0 0 0 1000 Error
Temperature Unit : (C)
Temperature Current Max Min Threshold Status
-------------------- ------- ----- ----- --------- ------
BCM53003(Active MSC) 45.0 47.0 43.0 47.5 Normal
POWER(Active MSC) 49.0 50.0 46.0 42.5 Error
BCM56544(Active MSC) 53.0 55.0 50.0 50.0 Error
Voltage(V) Current Max Min Threshold Status
------------------ ------- ------ ------ --------- ------
1.0VIN(Active MSC) 1.002 1.028 1.002 +/-8% Normal
1.2VIN(Active MSC) 1.212 1.212 1.201 +/-8% Normal
1.8VIN(Active MSC) 1.829 1.842 1.803 +/-8% Normal
3.3VIN(Active MSC) 3.325 3.325 3.308 +/-8% Normal
12VIN(Active MSC) 11.468 11.531 11.468 +/-5% Normal
H/W monitor status: Active

Содержание