Daikin FXSQ40P7VEB [227/370] Swing flap motor m1s abnormality

Daikin FXHQ100MAVS [227/370] Swing flap motor m1s abnormality
SiBE311209 Troubleshooting by Indication on the Remote Controller
Service Diagnosis 218
4.5 Swing Flap Motor (M1S) Abnormality
Remote
Controller
Display
A7
Applicable
Models
FXCQ, FXHQ, FXKQ
Method of Error
Detection
Utilizes ON/OFF of the limit switch when the motor turns
Error Decision
Conditions
When ON/OFF of the micro-switch for positioning cannot be reversed even though the swing
flap motor is energized for a specified amount of time (about 30 seconds).
Error code is displayed but the system operates continuously.
Supposed
Causes
Defective swing motor
Defective connection cable (power supply and limit switch)
Defective airflow direction adjusting flap-cam
Defective indoor unit PCB