Operation
3A6283H 37
12. For systems with water-heated hose: Pump
setting - Set the flow rate of the heating fluid by
opening the diaphragm pump (ZG) needle valve
(ZP) 45°- 60° open until the pump cycles 60-80
cycles/min (0.7-1.0 gpm or 2.6-3.8 l/min).
13. For systems with water-heated hose only:
Heater setting - Adjust the heater thermostat to the
desired temperature. The setting at the heater
output thermometer should be approximately 10 °F
(6 °C) higher than the desired paint temperature.
Never exceed the XP system 160 °F (71 °C)
maximum fluid temperature rating. See your Viscon
HP heater manual for instructions.
As a general guideline, heater knob settings are #7
for 105 °F (40 °C), #8 for 135 °F (57 °C), and #8 1/2
for 150 °F (65 °C).
NOTE: If the hose heat is not being used for more than
one hour, shut off the hot water heater (ZT) and
diaphragm pump (ZG) to lengthen heater life.
14. On initial start-up, proceed to Flushing on page 44.