Yaskawa CIMR-UU4A0216F [132/644] Auto tuning

Yaskawa CIMR-UU4A0240A [132/644] Auto tuning
Table 4.18 lists the data that must be entered for Auto-Tuning. Make sure the data is available before starting Auto-Tuning.
The necessary information is usually listed on the motor nameplate or in the motor test report provided by the motor
manufacturer. Refer to Subchart
A-3: Operation with Permanent Magnet Motors on page 124 for details on the Auto-Tuning
process and selection.
Figure 4.12 Motor Nameplate Example
Table 4.18 Auto-Tuning Input Data
Input Value
Input
Param.
Unit
Tuning Type (T2-01)
0
Motor Parameter Settings
1
Stationary
2
Stationary
Stator
Resis.
3
Z-Pulse
Offset
11
Back
EMF
Const.
13
High Freq.
Injection
14
Rotational
Control Mode A1-02 5, 6, 7 5 6, 7 5 6, 7 5, 6, 7 7 7 6, 7 5 6 7
Motor Code (Hex.) T2-02
<1> <1> <1>
Motor Type T2-03 YES YES YES YES YES
Motor Rated Power T2-04 kW YES YES YES YES YES YES YES
Motor Rated
Voltage
T2-05 Vac YES YES YES YES YES YES YES
Motor Rated
Current
T2-06 A YES YES YES YES YES YES YES YES
Motor Rated
Frequency
T2-07 Hz YES YES YES
Number of Motor
Poles
T2-08 YES YES YES YES YES YES YES
Motor Rated Speed T2-09 r/min YES YES YES YES
Stator Single-phase
Resistance
T2-10 Ω YES YES YES
d-Axis Inductance T2-11 mH YES YES YES
q-Axis Inductance T2-12 mH YES YES YES
Induced Voltage
Constant Unit
Selection
T2-13
mVs/
rad
(elec.)
YES YES YES
Voltage Constant
<3>
T2-14
mVmin
(mech.)
YES YES YES
Tuning Pull-in
Current
T2-15 % YES YES YES YES YES
PG Number of
Pulses Per
Revolution
T2-16 ppr
YES
<2>
YES
<2>
YES
<2>
YES
Z Pulse Offset T2-17
deg
(mech.)
YES
<2>
YES
<2>
YES
<2>
<1> Input the motor code when using a Yaskawa motor. Select “FFFF” when using a motor from another manufacturer.
<2> Input data is needed for CLV/PM only.
<3> Dependent upon T2-13 setting.
4.7 Auto-Tuning
132
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual