Yaskawa CIMR-UU4A0216F [539/644] B 8 defaults by drive model and duty rating nd hd

Yaskawa CIMR-UU4A0302F [539/644] B 8 defaults by drive model and duty rating nd hd
No. Name Unit Default Settings
Drive Model
4o0034 4o0040 4o0052 4o0065
C6-01 Drive Duty Selection HD ND HD ND HD ND HD ND
o2-04 Drive Model Selection Hex. 9C 9D 9E 9F
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
15 (20) 18.5 (25) 18.5 (25) 22 (30) 22 (30) 30 (40) 30 (40) 37 (50)
L2-02 Momentary Power Loss Ride-Thru Time s 0.9 1 1 1 1 1 1 1.1
L2-03
Momentary Power Loss Minimum
Baseblock Time
s 0.3 0.6 0.6 0.6 0.6 0.6 0.6 0.6
L2-04
Momentary Power Loss Voltage Recovery
Time
s 300 300 300 300 300 300 300 300
L8-02 Overheat Alarm Level °C 130 130 130 130 130 130 130 130
L8-35 Installation Method Selection 0 0 0 0 0 0 0 0
L8-38 Carrier Frequency Reduction Selection 1 1 1 1 1 1 1 1
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 10 10
n5-02 Motor Acceleration Time s 0.265 0.244 0.244 0.317 0.317 0.355 0.355 0.323
Table B.14 400 V Class Drives Default Settings by Drive Model Selection and ND/HD Settings
No. Name Unit Default Settings
Drive Model
4o0077 4o0096 4o0124 4o0156
C6-01 Drive Duty Selection HD ND HD ND HD ND HD ND
o2-04 Drive Model Selection Hex. A1 A2 A3 A4
E2-11
(E4-11)
Motor Rated Output
kW
(HP)
37 (50) 45 (60) 45 (60) 55 (75) 55 (75) 75 (100) 75 (100) 90 (125)
b3-04 V/f Gain during Speed Search % 100 100 100 100 100 80 80 60
b3-06 Output Current 1 during Speed Search 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.7
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.8
b8-03 Energy Saving Control Filter Time Constant s 0.50 0.50 0.50 0.50 0.50 2.00 2.00 2.00
b8-04 Energy Saving Coefficient Value 92.54 76.32 76.32 71.56 71.56 67.2 67.2 46.2
C5-17 (C5-37) Motor Inertia
kgm
2
0.220 0.273 0.273 0.333 0.333 0.490 0.490 0.900
C6-02 Carrier Frequency Selection 1 1 1 1 1 1 1 1
E2-01 (E4-01) Motor Rated Current A 52.3 65.6 65.6 79.7 79.7 95 95 130
E2-02 (E4-02) Motor Rated Slip Hz 1.8 1.33 1.33 1.6 1.6 1.46 1.46 1.39
E2-03 (E4-03) Motor No-Load Current A 10.9 19.1 19.1 22 22 24 24 36
E2-05 (E4-05) Motor Line-to-Line Resistance Ω 0.269 0.155 0.155 0.122 0.122 0.088 0.088 0.092
E2-06 (E4-06) Motor Leakage Inductance % 20.7 18.8 18.8 19.9 19.9 20 20 20
E2-10 (E4-10) Motor Iron Loss for Torque Compensation W 750 925 925 1125 1125 1260 1260 1600
E5-01 Motor Code Selection (for PM Motors) Hex. 1242 1242 1243 1243 1244 1244 1245 1245
L2-02 Momentary Power Loss Ride-Thru Time s 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.3
L2-03
Momentary Power Loss Minimum
Baseblock Time
s 0.6 0.6 0.6 0.6 0.6 1 1 1
L2-04
Momentary Power Loss Voltage Recovery
Time
s 300 300 300 300 300 300 300 300
L8-02 Overheat Alarm Level °C 130 130 130 130 130 130 130 130
L8-35 Installation Method Selection 0 0 0 0 0 0 0 0
L8-38 Carrier Frequency Reduction Selection 1 1 1 1 1 1 1 1
n1-03 Hunting Prevention Time Constant ms 10 10 10 10 10 10 30 30
n5-02 Motor Acceleration Time s 0.323 0.32 0.32 0.387 0.387 0.317 0.317 0.533
B.18 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual
539
B
Parameter List

Содержание