Yaskawa CIMR-UU4A0216F [55/644] Mechanical installation

Yaskawa CIMR-UU2A0081F [55/644] Mechanical installation
NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during installation and project
construction. Failure to comply could result in damage to the drive. Place a temporary cover over the top of the drive during installation.
Remove the temporary cover before drive start-up, as the cover will reduce ventilation and cause the drive to overheat.
External/Face-Mount
1.
Cut an opening in the enclosure panel for the digital operator as shown in Figure 2.11.
2.
Position the digital operator so the display faces outwards, and mount it to the enclosure panel as shown in Figure
2.10.
Digital Operator
M3 x 6
Phillips recessed
pan head machine screw x 2
Enclosure panel
Unit: mm
Figure 2.10 External/Face-Mount Installation
22
22
14
26
22
78
2
Unit: mm
Figure 2.11 Panel Cut-Out Dimensions (External/Face-Mount Installation)
2.2 Mechanical Installation
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual