5.7 H: Terminal Functions
H parameters assign functions to the external terminals.
u
H1: Multi-Function Digital Inputs
n
H1-01 to H1-08: Functions for Terminals S1 to S8
These parameters assign functions to the multi-function digital inputs. The various functions and settings are listed in Table
5.36.
No. Parameter Name
Setting
Range
Default
H1-01 Multi-Function Digital Input Terminal S1 Function Selection 1 to 9F
40 (F)
<1>
: Forward Run Command (2-Wire sequence)
H1-02 Multi-Function Digital Input Terminal S2 Function Selection 1 to 9F
41 (F)
<1>
: Reverse Run Command (2-Wire sequence)
H1-03 Multi-Function Digital Input Terminal S3 Function Selection 0 to 9F 24: External Fault (N.O., always detected, coast to stop)
H1-04 Multi-Function Digital Input Terminal S4 Function Selection 0 to 9F 14: Fault Reset
H1-05 Multi-Function Digital Input Terminal S5 Function Selection 0 to 9F
3 (0)
<1>
: Multi-Step Speed Reference 1
H1-06 Multi-Function Digital Input Terminal S6 Function Selection 0 to 9F
4 (3)
<1>
: Multi-Step Speed Reference 2
H1-07 Multi-Function Digital Input Terminal S7 Function Selection 0 to 9F
6 (4)
<1>
: Jog Reference Selection
H1-08 Multi-Function Digital Input Terminal S8 Function Selection 0 to 9F 8: External Baseblock Command
<1> Number appearing in parenthesis is the default value after performing a 3-Wire initialization (A1-03 = 3330).
Table 5.36 Multi-Function Digital Input Terminal Settings
Setting Function Page
0 3-Wire Sequence 247
1 LOCAL/REMOTE Selection 247
2 External Reference 1/2 Selection 248
3 Multi-Step Speed Reference 1
2484 Multi-Step Speed Reference 2
5 Multi-Step Speed Reference 3
6 Jog reference Selection 248
7 Accel/Decel Time Selection 1 248
8 Baseblock Command (N.O.)
248
9 Baseblock Command (N.C.)
A Accel/Decel Ramp Hold 248
B Drive Overheat Alarm (oH2) 249
C Analog Terminal Input Selection 249
D PG Encoder Disable 249
E ASR integral reset 249
F Through Mode 249
10 Up Command
249
11 Down Command
12 Forward Jog
250
13 Reverse Jog
14 Fault Reset 250
15 Fast Stop (N.O.) 250
16 Motor 2 Selection 251
17 Fast Stop (N.C.) 250
18 Timer Function Input 251
19 PID Disable 252
1A Accel/Decel Time Selection 2 252
1B Program Lockout 252
1E Reference Sample Hold 252
Setting Function Page
20 to 2F External Fault 252
30 PID Integral Reset 253
31 PID Integral Hold 253
32 Multi-Step Speed Reference 4 253
34 PID Soft Starter Cancel 253
35 PID Input Level Selection 253
40 Forward Run Command (2-Wire sequence)
253
41 Reverse Run Command (2-Wire sequence)
42 Run Command (2-Wire sequence 2)
254
43 FWD/REV Command (2-Wire sequence 2)
44 Offset Frequency 1
25445 Offset Frequency 2
46 Offset Frequency 3
47 Node Setup 254
60 DC Injection Braking Command 254
61 External Speed Search Command 1 254
62 External Speed Search Command 2 254
63 Field Weakening 254
67 Communications Test Mode 254
6A Drive Enabled 255
71 Speed/Torque Control Switch 255
72 Zero Servo 255
75 Up 2 Command
255
76 Down 2 Command
77 ASR Gain Switch 256
78 External Torque Reference Polarity Inversion 256
7E
Forward/Reverse Detection (V/f control with
simple PG)
256
7F PID Bi-directional Enable (Reserved) 256