A.1 Heavy Duty and Normal Duty Ratings
The capacity of the drive is based on two types of load characteristics: Heavy Duty (HD) and Normal Duty (ND). The user
can select HD
or ND torque depending on the application. Fans, pumps, and blowers should use ND, while other applications
generally use HD.
Refer to Table A.1 for the differences between HD and ND.
Table A.1 Selecting the Appropriate Load Rating
Setting Parameter C6-01 Rated Output Current Overload Tolerance
0: Heavy Duty
HD Rating varies by model
<1>
150% rated output current for 60 s
1: Normal Duty
(default)
ND Rating varies by model
<1>
120% rated output current for 60 s varies by model
<1> Refer to Power Ratings on page 431 for information on rating changes based on drive model.
Note: Differences between HD ratings and ND ratings for the drive include rated input and output current, overload capacity, and current limit.