Daikin REYQ34PY1 [407/438] Option list

Daikin REYQ34PY1 [407/438] Option list
Option List Si37-701
396 Appendix
4. Option List
4.1 Option List of Controllers
Operation Control System Optional Accessories
Note:
1. Installation box is necessary for each adaptor marked .
2. Up to 2 adaptors can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 installation boxes can be installed for each indoor unit.
5. Installation box is necessary for second adaptor.
6. Installation box is necessary for each adaptor.
Various PC Boards
System Configuration
Note:
1. Installation box for adaptor must be procured on site.
No.
3
4
Remote controller
Wireless
H/R
Wired
Simplified remote controller (Exposed type)
5 Adaptor for wiring
6-1 Wiring adaptor for electrical appendices (1)
6-2 Wiring adaptor for electrical appendices (2)
Remote controller for hotel use (Concealed type)
7 Remote sensor
9
External control adaptor for outdoor unit
(Must be installed on indoor units)
Type
Item
KRP1B59
DTA104A62
Wired remote controller with weekly schedule timer
KRCS01-1
KRP1B61
KRP2A62 KRP2A61
KRP4A53 KRP4A51
KRP2A61
KRP1B61
BRC3A61
BRC2C51
DTA104A61
8 Installation box for adaptor PC board
Note 2,3
KRP1D98
Note 3
KRP1C93
Note 2,3
KRP4A93
Note 2,3
KRP1B96
BRC2C51
BRC3A61
KRP1B61
KRP2A61
KRP4A51
KRP2A62
KRP2A61
KRP4A52 KRP4A51 KRP4A51
Note 4,6
KRP1B101
DTA104A61DTA104A53DTA104A61 DTA104A61 DTA104A62DTA104A61
BRC1D61
KRP1C3KRP1B56
KRP2A53
KRP4A54
KRP1B61
KRP2A61
KRP4A53
KRCS01-1
Note 4,6
KRP1B101
KRP1B57
KRP2A62
KRP4A51
2
1
KRCS01-1
Note 5
KRP4A91
BRC1C62
FXCQ-M FXFQ-M FXKQ-MA FXSQ-M
FXDQ-P
FXDQ-NA
FXAQ-MA
FXLQ-MA
FXNQ-MA
BRC7C62 BRC7E61W BRC4C61 BRC4C62 BRC7E618 BRC4C62BRC4C62
FXMQ-MA
BRC4C62
FXDYQ-M
BRC4C62
FXHQ-MA
BRC7E63W
FXZQ-M8
BRC7E530W7
No. Part name Model No. Function
1 Adaptor for wiring
KRP1B56
KRP1B57
KRP1B59
KRP1B61
KRP1C3
PC board when equipped with auxiliary electric heater in the indoor unit.
2 DIII-NET Expander Adaptor DTA109A51
Up to 1,024 units can be centrally controlled in 64 different groups.
Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of
branches: 16) apply to each adaptor.
•Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and
monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one
system.
DCS302CA61
Central remote controller1
•Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units
(128 units). Can turn units ON/OFF twice per day.
DST301BA61
Schedule timer
3
•Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and
operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.
DCS301BA61
Unified ON/OFF controller2
KJB212AElectrical box with earth terminal (2 blocks)2-1
KEK26-1Noise filter (for electromagnetic interface use only)2-2
KJB311AElectrical box with earth terminal (3 blocks)1-1
DTA102A52
Interface adaptor for SkyAir-series4
DTA107A55
5
DTA103A51
Wiring adaptor for other air-conditioner6
No. Part name Model No. Function
•Up to 1024 units can be centrally controlled in 64 different groups.
•Wiring restrictions (max. lengh : 1,000m, total wiring lengh : 2,000m, max. number of branches : 16)
apply to each adaptor.
DTA109A51
D -NET
Expander Adaptor
7
•Fixing plate for DTA109A51KRP4A92
Mounting plate7-1
•Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET
communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be
controlled.
For UAT
(
Y
)
-K
(
A
)
,FD-K
For SkyAir, FD
(
Y
)
M-FA, FDY-KA
FDYB-KA, FVY(P)J-A
Central control adaptor kit