11
Table 1 Recharging ranges of batteries
(2) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown
in Table 2.
Table 2 Charging time (At 20°C)
The pilot lamp goes off to indicate that the battery
is fully charged.
The battery charging time becomes longer when a
temperature is low or the voltage of the power
source is too low.
When the pilot lamp does not go off even if more
than 120 minutes have elapsed after starting of the
charging, stop the charging and contact your
HITACHI AUTHORIZED SERVICE CENTER.
CAUTION
If the battery is heated due to direct sunlight,
etc., just after operation, the charger pilot lamp
may not light up. At that time, cool the battery
first, then start charging.
3. Disconnect the charger’s power cord from the
receptacle
4. Hold the charger firmly and pull out the battery
NOTE
After charging, pull out batteries from the charger
first, and then keep the batteries properly.
Regarding electric discharge in case of new batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
and normal time required for recharging will be
restored by recharging the batteries 2 – 3 times.
How to make the batteries perform longer.
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a
while.
UC18YGH
Before using the power tool, charge the battery as
follows.
1. Connect the charger’s power cord to the receptacle.
When connecting the plug of the charger to a
receptacle, the pilot lamp will blink in red
(At 1-second intervals).
2. Insert the battery into the charger.
Firmly insert the battery into the charger till it
contacts the bottom of the charger and checking
the polarities as shown in Fig. 4.
CAUTION:
If the batteries are inserted in the reverse direction,
not only recharging will become impossible, but it
may also cause problems in the charger such as
a deformed recharging terminal.
3. Charging
When inserting a battery in the charger, the pilot
lamp will light up continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red (At 1-second intervals). (See
Table 3)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown
in Table 3, according to the condition of the charger
or the rechargeable battery.
Temperatures at
Rechargeable batteries which the battery
can be recharged
EB912S, EB914S, EB9B,
EB1212S, EB1214S,
0°C – 45°C
EB1220BL, EB1412S,
EB1414S, EB14B,
EB1814SL, EB1820L
Charger
UC18YG
Battery
EB912S, EB914S,
EB1212S, EB1214S,
Approx. 30 min.
EB1412S, EB1414S,
EB1814SL
EB9B, EB1220BL, EB14B,
Approx. 50 min.
EB1820L
01Eng_DS9DVF3_EE 1/20/09, 16:0011

Содержание

English Table 1 Recharging ranges of batteries How to make the batteries perform longer Rechargeable batteries Temperatures at which the battery can be recharged EB912S EB914S EB9B EB1212S EB1214S EB1220BL EB1412S EB1414S EB14B EB1814SL EB1820L 0 C 45 C 2 Regarding recharging time Depending on the combination of the charger and batteries the charging time will become as shown in Table 2 Table 2 Charging time At 20 C Charger Batte ry UC18YG EB912S EB914S EB1212S EB1214S EB1412S EB1414S EB1814SL Approx 30 min EB9B EB1220BL EB14B EB1820L Approx 50 min The pilot lamp goes off to indicate that the battery is fully charged The battery charging time becomes longer when a temperature is low or the voltage of the power source is too low When the pilot lamp does not go off even if more than 120 minutes have elapsed after starting of the charging stop the charging and contact your HITACHI AUTHORIZED SERVICE CENTER CAUTION If the battery is heated due to direct sunlight etc just after operation the charger pilot lamp may not light up At that time cool the battery first then start charging 3 Disconnect the charger s power cord from the receptacle 4 Hold the charger firmly and pull out the battery NOTE After charging pull out batteries from the charger first and then keep the batteries properly Regarding electric discharge in case of new batteries etc As the internal chemical substance of new batteries and batteries that have not been used for an extended period is not activated the electric discharge might be low when using them the first and second time This is a temporary phenomenon and normal time required for recharging will be restored by recharging the batteries 2 3 times 11 1 Recharge the batteries before they become completely exhausted When you feel that the power of the tool becomes weaker stop using the tool and recharge its battery If you continue to use the tool and exhaust the electric current the battery may be damaged and its life will become shorter 2 Avoid recharging at high temperatures A rechargeable battery will be hot immediately after use If such a battery is recharged immediately after use its internal chemical substance will deteriorate and the battery life will be shortened Leave the battery and recharge it after it has cooled for a while UC18YGH Before using the power tool charge the battery as follows 1 Connect the charger s power cord to the receptacle When connecting the plug of the charger to a receptacle the pilot lamp will blink in red At 1 second intervals 2 Insert the battery into the charger Firmly insert the battery into the charger till it contacts the bottom of the charger and checking the polarities as shown in Fig 4 CAUTION O If the batteries are inserted in the reverse direction not only recharging will become impossible but it may also cause problems in the charger such as a deformed recharging terminal 3 Charging When inserting a battery in the charger the pilot lamp will light up continuously in red When the battery becomes fully recharged the pilot lamp will blink in red At 1 second intervals See Table 3 1 Pilot lamp indication The indications of the pilot lamp will be as shown in Table 3 according to the condition of the charger or the rechargeable battery