EDS-828 Series Getting Started
2-3
3. The Communication Parameter page of the Property window opens. Select the appropriate COM port
for Console Connection, 115200 for Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits.
4. Click on the Terminal tab, and select VT100 for Terminal Type. Click on OK to continue.
5. Type 1 to select ansi/VT100 terminal type, and then press Enter.
6. The Console login screen will appear. Press Enter to open the Account pop-up selector and then select
either admin or user. Use the keyboards down arrow to move the cursor to the Password field, enter the
Console Password (this is the same as the Web Browser password; leave the Password field blank if a
console password has not been set), and then press Enter.