Email Alarm Events Settings
Event Types
Event Types can be divided into two basic groups: System Events and Port Events. System Events are
related to the overall function of the switch, whereas Port Events are related to the activity of a specific port.
System Event Warning e-mail is sent when…
Switch Cold Start Power is cut off and then reconnected.
Switch Warm Start The EDS-828 is rebooted, such as when network parameters are changed (IP
address, subnet mask, etc.).
Power Transition (OnOff) The EDS-828 is powered down.
Power Transition (OffOn) The EDS-828 is powered up.
DI1 (OnOff) Digital Input 1 is triggered by on to off transition
DI1 (OffOn) Digital Input 1 is triggered by off to on transition
DI2 (OnOff) Digital Input 2 is triggered by on to off transition
DI2 (OffOn) Digital Input 2 is triggered by off to on transition
Configuration Change
Activated
Any configuration item has been changed.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have changed their position (applies
only to the root of the tree).
If the Master of the Turbo Ring has changed or the backup path is activated.
Authentication Failure An incorrect password is entered.
Port Event Warning e-mail is sent when…
Link-on The port is connected to another device.
Link-off The port is disconnected (e.g., the cable is pulled out, or the opposing device
shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-
Threshold for that port (provided this
item is Enabled).
Traffic-Threshold (%) Enter a nonzero number if the port’s Traffic-Overload item is Enabled.
Traffic-Duration (sec.) A Traffic-Overload warning is sent every Traffic-Duration seconds if the
average Traffic-Threshold is surpassed during that time period.