Moxa EDS-82810G [25/113] System file update by local import export

Moxa EDS-82810G [25/113] System file update by local import export
EDS-828 Series Featured Functions
3-12
Configuration file path and name
Setting Description Factory Default
Max. 40 Characters The path and file name of the EDS-828s configuration file in
the TFTP server.
None
Firmware file path and name
Setting Description Factory Default
Max. 40 Characters The path and file name of the EDS-828s firmware file. None
Log file path and name
Setting Description Factory Default
Max. 40 Characters The path and file name of the EDS-828s log file None
After setting up the desired path and file name, click on Activate to save the setting, and then click on
Download to download the prepared file from the remote TFTP server, or click on Upload to upload the
desired file to the remote TFTP server.
System File UpdateBy Local Import/Export
Configuration File
To export the configuration file of this EDS-828, click on Export to save it to the local host.
Log File
To export the Log file of this EDS-828, click on Export and save it to the local host.
NOTE
Some operating systems will open the configuration file and log file directly in the web page. In such cases,
right click on the “Export” button to save a f
ile.
Upgrade Firmware
To import the firmware file of this EDS-828, click on Browse to select the firmware file already saved on your
computer. The upgrade procedure will proceed automatically after clicking on Import.
Upload Configure Data
To import the configuration file of this EDS-828, click on Browse to select the configuration file already saved
on your computer. The upgrade procedure will proceed automatically after clicking on Import.