Moxa EDS-82810G [24/113] System file update by remote tftp

Moxa EDS-82810G [24/113] System file update by remote tftp
EDS-828 Series Featured Functions
3-11
Configuration IEEE 1588/PTP
Setting Description Factory Default
Clock Mode Support software-based IEEE 1588(PTP) mode Disable
Sync Interval Period for sending synchronization message (in seconds) Disable
Sub-domain Name Support _DFLT(Default) domain only _DFLT
Status
Setting Description Factory Default
Offset To Master (nsec)
Deviation between local time and the reference clock (in
nanoseconds).
Grandmaster UUID When the clock has a port in PTP_SLAVE state, this member’s
value is the value of the grand master clock's Uuid field of the
last Sync message received from the parent of the slave port.
Parent UUID When the clock has a port in PTP_SLAVE state, this member’s
value is the value of the source-Uuid field of the last Sync
message received from the parent of the slave port.
Clock Stratum The stratum number describes one measure of the quality of a
clock. Each clock is characterized by a stratum number used by
the best master clock algorithm as one parameter of clock
quality.
4
Clock Identifier Properties of the clock. DFLT
PTP Port Settings
Setting Description Factory Default
Port Enable Enable or disable PTP port operation. None
Port Status Display PTP port real status. PTP_DISABLED
System File UpdateBy Remote TFTP
The EDS-828 supports saving your configuration file to a remote TFTP server or local host to allow other
EDS-828 switches to use the same configuration at a later time, or saving the Log file for future reference.
Loading pre-saved firmware or a configuration file from the TFTP server or local host is also supported for easy
upgrading or configuration of the EDS-828.
TFTP Server IP/Name
Setting Description Factory Default
IP Address of TFTP
Server
The IP or name of the remote TFTP server. Must be set up
before downloading or uploading files.
None