High Performance Vector Control/TorqueControl Inverter User Manual
26 Chapter 3 Wiring of Incerter
Note: The short circuit plate between terminal +24V and terminal PLC must be removed and short
circuit plate shall be connected between PLC and COM terminals.
When the external power supply is used, the external controller adopts NPN sink current wiring
mode.
Note: The short circuit plate between terminal +24V and terminal PLC must be removed.
When the external power supply is used, the external controller adopts PNP draw-off current wiring
mode.
User
controller
Inside of inverter
The near end of the
shieldin
g
cable is grounded
+24
User
Controlle
r
+24V
The near end of
the shielding cable
is grounded
User
controller
Inside of inverter
The near end of the
shielding cable is grounded
+24
User
Controller
Inside of inverter
+24V
The near end of
the shielding cable
is grounded