Tecorp HC2V9G4075 [77/182] Group pc communication parameters

Tecorp HC2V9G4011 [77/182] Group pc communication parameters
High Performance Vector Control/Torque Control Inverter User Manual
Chapter 5 List of Parameters 55
2: Adjustment is invalid
Thousands place:
0: With integral function;
1: Without integral function
Pb.09
Operation panel /
integral rate
2.0
0.1 ~ 50.0 s 0.1 ~ 50.0s
Pb.10
Terminal UP/DN digital
regulating
frequency control
0001
0000 ~0221
/
Ones place: Action upon power off
0: Save upon power off;
1: Clear upon power off
Tens place: Action upon stopping
0: Hold upon stopping;
1: Clear upon stop;
2: Clear upon standby
Hundreds place: Terminal UP/DN
adjustment setting
0: Only enabled when main input is
P0.05 open loop digital frequency
input;
1: Adjustment is valid;
2: Adjustment is invalid
Thousands place:
0: With integral function;
1: Without integral function
Pb.11
Terminal UP/DN integral
rate
2.0
0.1 ~ 50.0 s 0.1 ~ 50.0s
Pb.15
Restart automatically after
power resumes narmal
0 0 ~ 1 / ×
0: No action;
1: Action
Pb.16 Waiting time for restart 0.5
0.0 ~ 20.0 s 0.0 ~ 20.0s
Pb.17 Preset frequency 0.00
0.00 ~ 300.00
Hz × 0.00 ~ 300.00Hz
Pb.18
Preset frequency operating
time
0.0
0.0 ~ 3600.0
s × 0.0 ~ 3600.0s
Pb.19
Upper limit of zero
frequency operation
0.00
0.00 ~ 300.00
Hz × 0.00 ~ 300.00Hz
Pb.20
Lower limit of zero
frequency operation
0.00
0.00 ~ 300.00
Hz × 0.00 ~ 300.00Hz
Pb.21 Reserved 0 0 ~ 1 / × Reserved
Pb.22 Reserved 380.0
0.0 ~ 380.0
V × Reserved
Pb.23 Parameter copy 0 0 ~ 5 / ×
0: No function;
1: Parameter uploading;
2: Parameter downloading (without
motor parameters);
3: Parameter downloading (with
motor parameters);
4: Parameter storage enable
(upload is prohibited);
5: Parameter storage disable
(upload is allowed)
Group PC Communication Parameters
PC.00 Communication baud rate
6 4 ~ 8 bps
4: 4800 bps; 5: 9600 bps;
6: 19200 bps; 7: 38400 bps;
8: 57600 bps
PC.01 Data format 0 0 ~ 2 /
0: 1-8-1 format, no parity;
1: 1-8-1 format, even parity;
2: 1-8-1 format, odd parity
PC.02 Local address 1 1 ~ 247 / 1 ~ 247, 0 is broadcasting address
PC.03 PC Reserved 1 0 0 ~ 65535 / * Reserved
PC.04 Master-slave mode 0 0 ~ 2 /
0: SCIA slave mode, SCIB slave
mode;
1: SCIA master mode,SCIB slave
mode;
2: SCIA slave mode,SCIB master
mode
PC.05 Operation address from 0 0 ~ 2 / Master preset frequency written in