42 Chapter 4 Using Instructions of Operation Panel
Note
If fault happens, please judge the fault
causes and clear the fault according to
7.1 Fault and alarm information list.
If motor can without connecting the load
rotating auto tuning can be selected
(P9.15=2),otherwise only static auto
tuning can be selected .When enabling
the auto tuning please ensure the motor is
in standstill status .If over voltage or over
current happens in auto tuning process,
you can prolong the acceleration and
deceleration times of P0.08 and P0.09.
Upon vector control 2, the loads
must be detached before the rotating
auto tuning is performed.
Setting P0.01=3 restore the
factory setting.