Daikin RWEYQ28PY1 [66/342] C heating and simultaneous cooling heating operation mode when the outdoor water cooled heat exchanger is used as evaporator in case there are indoor units operating with cooling thermostat on

Daikin RWEYQ30PY1 [66/342] C heating and simultaneous cooling heating operation mode when the outdoor water cooled heat exchanger is used as evaporator in case there are indoor units operating with cooling thermostat on
Si30-813 Refrigerant Flow for Each Operation Mode
Refrigerant Circuit 55
C. Heating and simultaneous cooling heating operation mode (When the outdoor water cooled heat exchanger
is used as evaporator.)
(In case there are indoor units operating with cooling thermostat "ON".)
Suction gas pipe
Discharge gas pipe
Liquid pipe
High temperature, high pressure gas
High temperature, high pressure liquid
Low temperature, low pressure liquid or gas
E3 control
ON-OFF control by
receiver pressurerising
control
Capillary
tube
Three way
valve
Capillary tube
Solenoid valve
Check valve
Filter
Indoor unit (Thermostat "ON")
Fan ON
To other indoor units
" ON "
Cooling
Heating
Heating
Heat exchanger
Fan
Electronic
expansion valve
Filter Filter
Indoor unit (Thermostat "ON")
Fan ON
" ON "
Heat exchanger
Fan
Electronic
expansion valve
Filter Filter
Indoor unit (Thermostat "ON")
Fan ON
" ON "
Heat exchanger
Fan
Electronic
expansion valve
Filter Filter
Indoor unit
operation
Bs unit
Bs unit
Bs unit
Outside unit
Indoor unit
Indoor unit
Indoor unit
Capillary
tube
Three way
valve
Capillary tube
Solenoid valve
Check valve
Filter
Capillary
tube
Three way
valve
Capillary tube
Solenoid valve
Check valve
Filter
Oil
separator

Содержание

Скачать