5 About the units and options
Installer reference guide
13
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1A – 2016.02
EKRUCBL6 contains following languages: English, Croatian,
Hungarian, Estonian.
EKRUCBL7 contains following languages: English, German,
Russian, Danish.
Languages on the user interface can be uploaded by PC software or
copied from an user interface to the other.
For installation instructions, see "7.11.9 To connect the user
interface"on page41.
Simplified user interface (EKRUCBS)
The simplified user interface can only be used in combination with
the main user interface.
The simplified user interface acts as room thermostat and needs
to be installed in the room that you want it to control.
For installation instructions, see the installation and operation
manual of the simplified user interface.
Room thermostat (EKRTWA, EKRTR1, RTRNETA)
You can connect an optional room thermostat to the indoor unit. This
thermostat can either be wired (EKRTWA) or wireless (EKRTR1and
RTRNETA). Thermostat RTRNETA can only be used in heating-only
systems.
For installation instructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Digital I/O PCB (EKRP1HB)
The digital I/O PCB is required to provide the following signals:
Alarm output
Space heating/cooling On/OFF output
For installation instructions, see the installation manual of the digital
I/O PCB and the addendum book for optional equipment.
Demand PCB (EKRP1AHTA)
To enable the power saving consumption control by digital inputs
you must install the demand PCB.
For installation instructions, see the installation manual of the
demand PCB and addendum book for optional equipment.
Remote indoor sensor (KRCS01-1)
By default the internal user interface sensor will be used as room
temperature sensor.
As an option the remote indoor sensor can be installed to measure
the room temperature on another location.
For installation instructions, see the installation manual of the remote
indoor sensor and addendum book for optional equipment.
INFORMATION
The remote indoor sensor can only be used in case the
user interface is configured with room thermostat
functionality.
You can only connect either the remote indoor sensor
or the remote outdoor sensor.
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure
the outdoor temperature.
As an option the remote outdoor sensor can be installed to measure
the outdoor temperature on another location (e.g. to avoid direct
sunlight) to have an improved system behaviour.
For installation instructions, see the installation manual of the remote
outdoor sensor.
INFORMATION
You can only connect either the remote indoor sensor or
the remote outdoor sensor.
PC configurator (EKPCCAB)
The PC cable makes a connection between the switch box of the
indoor unit and a PC. It gives the possibility to upload different
language files to the user interface and indoor parameters to the
indoor unit. For the available language files, contact your local
dealer.
The software and corresponding operating instructions are available
on http://www.daikineurope.com/support-and-manuals/software-
downloads/.
For installation instructions, see the installation manual of the PC
cable and "8Configuration"on page50.
Heat pump convector (FWXV)
For providing space heating/cooling, it is possible to use heat pump
convectors (FWXV).
For installation instructions, refer to the installation manual of the
heat pump convectors, and the addendum book for optional
equipment.
Solar kit (EKSRPS3)
The solar kit is required to connect the solar application with the
domestic hot water tank.
For installation, see the installation manual of the solar kit and
addendum book for optional equipment.
Domestic hot water tank
The domestic hot water tank can be connected to the indoor unit for
providing domestic hot water. The polypropylene tank is available in
2 types:
EKHWP300B: 300l.
EKHWP500B: 500l.
Use the appropriate connection kit for the tank (EKEPHT3H), as
described in the addendum book for optional equipment.
Connection kit for the tank (EKEPHT3H)
Use the connection kit to connect the domestic hot water tank to the
indoor unit.
For installation instructions, see the installation manual of the
connection kit.
Drain pan kit (EKHYDP1)
The drain pan kit is required for heating/cooling units. It does NOT
have to be used with heating only units.
For installation instructions, see the installation manual of the drain
pan kit.
Mounting kit (EKHYMNT1A, EKHYMNT2A, EKHYMNT3A)
Mounting fixture for easy installation of the hybrid system (heat
pump module + gas boiler module). For the selection of the correct
kit, see the combination table.
For installation instructions, see the installation manual of the
mounting kit.
Filling loop kit (EKFL1A)
Filling loop for easy filling of the water circuit. This kit can only be
used in combination with mounting kit EKHYMNT1A.
For installation instructions, see the installation manual of the filling
loop kit.