12 Maintenance and service
Installer reference guide
86
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1A – 2016.02
After servicing, complete the relevant Service Interval Record
section of the Benchmark Checklist located on the backpages of this
document.
NOTICE
Maintenance must be done by an authorised installer or
service agent.
We recommend to do maintenance at least once a year.
However, applicable legislation might require shorter
maintenance intervals.
12.1 Overview: Maintenance and
service
This chapter contains information about:
The yearly maintenance of the outdoor unit
The yearly maintenance of the indoor unit
Cleaning the gas boiler
12.2 Maintenance safety precautions
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING
NOTICE:Risk of electrostatic discharge
Before performing any maintenance or service work, touch
a metal part of the unit in order to eliminate static electricity
and to protect the PCB.
12.2.1 Opening the indoor unit
See "7.2.3 To open the switch box cover of the indoor unit" on
page24.
12.3 Checklist for yearly maintenance
of the outdoor unit
Check the following at least once a year:
Outdoor unit heat exchanger.
The heat exchanger of the outdoor unit can get blocked up due to
dust, dirt, leaves, etc. It is recommended to clean the heat
exchanger yearly. A blocked heat exchanger can lead to too low
pressure or too high pressure leading to worse performance.
12.4 Checklist for yearly maintenance
of the indoor unit
Check the following at least once a year:
Water pressure
Water filter
Water pressure relief valve
Pressure relief valve of the domestic hot water tank
Switch box
Water pressure
Check whether the water pressure is above 1bar. If it is lower, add
water.
Water filter
Clean the water filter.
NOTICE
Handle the water filter with care. Do NOT use excessive
force when you reinsert the water filter so as NOT to
damage the water filter mesh.
1 3
2
5
4
Water pressure relief valve
Open the valve and check if it operates correctly. The water may be
very hot!
Checkpoints are:
The water flow coming from the relief valve is high enough, no
blockage of the valve or in between piping is suspected.
Dirty water coming out of the relief valve:
open the valve until the discharged water does NOT contain dirt
anymore
flush the system and install an additional water filter (a
magnetic cyclone filter is preferable).
To make sure this water originates from the tank, check after a tank
heat up cycle.
It is recommended to do this maintenance more frequently.
Relief valve of the domestic hot water tank (field supply)
Open the valve and check the correct operation. Water may be very
hot!
Checkpoints are:
The water flow coming from the relief valve is high enough, no
blockage of the valve or in between piping is suspected.
Dirty water coming out of the relief valve:
open the valve until the discharged water does not contain dirt
anymore
flush and clean the complete tank, including the piping between
the relief valve and cold water inlet.
To make sure this water originates from the tank, check after a tank
heat up cycle.
It is recommended to do this maintenance more frequently.
Switch box
Carry out a thorough visual inspection of the switchbox and look for
obvious defects such as loose connections or defective wiring.
WARNING
If the internal wiring is damaged, it has to be replaced by
the manufacturer, its service agent or similarly qualified
persons.
12.5 To disassemble the gas boiler
1 Turn off the appliance.
2 Turn off the main power supply of the appliance.
3 Close the gas tap.
4 Remove the front panel.