Daikin EHYKOMB33AA2 [134/136] P353731 1d 2015 2 setting is not applicable for this unit hyhbh x aav3

Daikin EHYKOMB33AA2 [134/136] P353731 1d 2015 2 setting is not applicable for this unit hyhbh x aav3
8/8
Breadcrumb Field code Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
Setting name
A.8 [B-02]
0
A.8 [B-03]
0
A.8 [B-04]
0
A.8 [C-00] R/W
0: Solar priority
1: Heat
p
um
p
p
riorit
y
A.8 [C-01]
0
A.8 [C-02]
0
A.8 [C-03]
0
A.8 [C-04]
3
A.8 [C-05] R/W
1: Thermo ON/OFF
2: C/H re
q
uest
A.8 [C-06] R/W 0: -
1: Thermo ON/OFF
2: C/H re
q
ues
t
A.8 [C-07] R/W 0: LWT control
1: Ext RT control
2: RT control
A.8 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.8 [C-09] R/W
0: Normally open
1: Normall
y
closed
A.8 [C-0A] R/W
0: Disable
1: Enable
A.8 [C-0C] R/W 0~7
4
A.8 [C-0D] R/W 0~7
4
A.8 [C-0E] R/W 0~7
4
A.8 [D-00]
0
A.8 [D-01] R/W
0: No
1: Active open
2: Active closed
A.8 [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
([
E-06
]
=1
)
A.8 [D-03] R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C
(
from -4 to 4°C
)
A.8 [D-04] R/W
0: No
1: Pwr consm
ctrl
A.8 [D-05]
1
A.8 [D-07] R/W
0: No
1: Yes
A.8 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.8 [D-09]
0
A.8 [D-0A] R/W
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
A.8 [D-0B]
2
A.8 [D-0C] R/W 0~49
20
A.8 [D-0D] R/W 0~49
20
A.8 [D-0E] R/W 0~49
15
A.8 [E-00] R/O
0~5
3: H
y
brid
A.8 [E-01] R/O
0: 08
A.8 [E-02] R/O
*HYHBH05+08: 1: Type 2
*HYHBX08: 0: T
yp
e 1
A.8 [E-03]
0
A.8 [E-04] R/O
1: Yes
A.8 [E-05] R/W
0: No
1: Yes
A.8 [E-06] R/W
0: No
1: Yes
A.8 [E-07] R/W
0~6
4: Type 5
6: T
yp
e 7
A.8 [E-08] R/W 0: Disabled
1: Enabled
A.8 [E-09]
0
A.8 [E-0A]
0
A.8 [E-0B] R/O
0
(
#
)
A.8 [E-0C]
0
A.8 [F-00] R/W
0: Disabled
1: Enabled
A.8 [F-01] R/W 10~35°C, step: 1°C
20°C
A.8 [F-02]
3
A.8 [F-03]
5
A.8 [F-04]
0
A.8 [F-05]
0
A.8 [F-06]
0
A.8 [F-09] R/W
0: Disabled
1: Enabled
A.8 [F-0A]
0
A.8 [F-0B] R/W
0: No
1: Yes
A.8 [F-0C] R/W 0: No
1: Yes
A.8 [F-0D] R/W 0: Continuous
1: Sample
2: Re
q
ues
t
Is a DHW tank installed in the system?
Can the system prepare domestic hot water?
--
--
--
Domestic heating water priority.
--
--
--
--
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
Which type of external sensor is installed?
What is the required alarm output contact type?
Indoor quick heat-up function
High electricity price decimal (Do not use)
Medium electricity price decimal (Do not use)
Low electricity price decimal (Do not use)
--
Contact type of preferential kWh rate PS installation?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
--
Is a solar kit connected?
Is an external kWh meter used for power measurement?
--
Is an external gas meter used for power measurement?
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
--
--
Is the power saving function available on the outdoor unit?
Power saving function for outdoor unit.
--
--
Pump operation allowed outside range.
--
Is a bi-zone kit installed?
What kind of DHW tank is installed?
Close shut-off valve during thermo OFF?
Above which outdoor temperature is cooling allowed?
--
--
Close shut-off valve during cooling?
What is the pump operation mode?
--
--
--
Pump operation during flow abnormality.
4P353731-1D - 2015.02 (#) Setting is not applicable for this unit. *HYHBH/X*AAV3