Daikin EHYKOMB33AA2 [50/136] Configuration

Daikin EHYKOMB33AA2 [50/136] Configuration
8 Configuration
Installer reference guide
50
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1A – 2016.02
f Finishing tape
2 Install the service cover.
7.14.2 To close the outdoor unit
1 Close the switch box cover.
2 Close the service cover.
NOTICE
When closing the outdoor unit cover, make sure that the
tightening torque does NOT exceed 4.1N•m.
7.15 Finishing the indoor unit
installation
7.15.1 To close the indoor unit
1 Close the switch box.
2 Mount the side plate to the unit.
3 Mount the top plate.
NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1N•m.
Before doing the configuration of the heat pump module, make sure
that the hybrid module and gas boiler are installed correctly.
7.16 Finishing the gas boiler
installation
7.16.1 To purge the gas supply
1 Turn once the screw counterclockwise.
Result: Gas supply will purge air.
2 Check all connections for leakage.
3 Check the gas supply pressure.
INFORMATION
Make sure the working inlet pressure does NOT interfere
with other gas appliances installed.
7.16.2 To close the gas boiler
1 Hook the top of the front panel into the top of the gas boiler.
2 Tilt the bottom side of the front panel towards the gas boiler.
3 Screw both screws of the cover.
4 Close the display cover.
7.16.3 To install the cover plate
8 Configuration
8.1 Indoor unit
8.1.1 Overview: Configuration
This chapter describes what you have to do and know to configure
the system after it is installed.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following: