Daikin EHYKOMB33AA2 [27/136] Installation

Daikin EHYKOMB33AA2 [27/136] Installation
7 Installation
Installer reference guide
27
EVLQ05+08CAV3 + EHYHBH05AA + EHYHBH/X08AA +
EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1A – 2016.02
An additional drain pan kit (EKDP008CA) can be used to gather the
drain water. The drain pan kit consists of:
a
b
a Drain pan
b U-beams
283 mm
580 mm
7.3.6 To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1 Prepare 2 cables as indicated in the following illustration (field
supply).
2 Place the 2 cables over the outdoor unit.
3 Insert a rubber sheet between the cables and the outdoor unit
to prevent the cable from scratching the paint (field supply).
4 Attach the cable’s ends. Tighten those ends.
7.4 Mounting the indoor unit
7.4.1 About mounting the indoor unit
When
You have to mount the outdoor and indoor unit before you can
connect the refrigerant and water piping.
Typical workflow
Mounting the indoor unit typically consists of the following stages:
1 Installing the indoor unit.
7.4.2 Precautions when mounting the indoor
unit
INFORMATION
Also read the precautions and requirements in the
following chapters:
General safety precautions
Preparation
7.4.3 To install the indoor unit
1 Put the installation pattern (see box) on the wall and follow the
steps as shown below.
21 3
2 Fix the wall bracket to the wall with 2 M8 bolts.

Содержание

Скачать