Daikin RXS25C2VMB [55/246] Power airflow dual flaps wide angle louvers and auto swing

Daikin ARXS25CVMB [55/246] Power airflow dual flaps wide angle louvers and auto swing
Main Functions SiENBE04-401A
46 Function and Control
1.2 Power-Airflow Dual Flaps, Wide-Angle Louvers and
Auto-Swing
Power-Airflow
Dual Flaps
The large flaps send a large volume of air downwards to the floor. The flap provides an optimum
control area in cooling, heating and dry mode.
Heating Mode
During heating mode, the large flap enables direct warm air straight downwards. The flap
presses the warm air above the floor to reach the entire room.
Cooling Mode
During cooling mode, the flap retracts into the indoor unit. Then, cool air can be blown far and
pervaded all over the room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing The following table explains the auto swing process for heating, cooling, dry and fan :
Vertical Swing (up and down)
Horizontal Swing
(right and left: manual)
Cooling / Dry / Fan Heating Heating, Cooling
(R2946)
25˚
25˚
30˚
30˚
(R4013)
50˚
50˚
(R2817)

Содержание